EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Comparison of batch and continuous multi-column capture of monoclonal antibodies with convective diffusive membrane adsorbers

Fabian Schmitz, Mirjana Minceva, Markus Kampmann

Journal of Chromatography A · 2024

DOI: 10.1016/j.chroma.2024.465201 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Chromatography A, 2024. Verfasst von Fabian Schmitz und 2 weiteren Autor:innen. Beteiligte Einrichtung: Biothermodynamics, TUM School of Life Sciences, Technical University of Munich, Freising, Germany; Corporate Research, Sartorius Stedim Biotech GmbH,…. Hauptthemen laut MEDLINE: Antibodies, Monoclonal, Membranes, Artificial, Chromatography, Affinity. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Protein A affinity membrane adsorbers are a promising alternative to resins to intensify the manufacturing of monoclonal antibodies. This study examined the process performance of convective diffusive membrane adsorbers operated in batch and continuous multi-column mode. Therefore, three different processes were compared regarding membrane utilization, productivity, and buffer consumption: the batch process, the rapid cycling parallel multi-column chromatography process, and the rapid cycling simulated moving bed process. The influence of the monoclonal antibody loading concentration (between 0.5 g L-1 and 5.2 g L-1) and the loading flow rate (between 1.25 MV min-1 and 10 MV min-1) on the monoclonal antibody binding behavior of the membrane adsorber were studied with breakthrough curve experiments. The determined breakthrough curves were used to calculate the monoclonal antibody dynamic binding capacity, the duration of the loading steps for each process, and the number of required membrane adsorbers for the continuous processes rapid cycling parallel multi-column chromatography and rapid cycling simulated moving bed. The highest productivity for the batch (176 g L-1 h-1) and rapid cycling parallel multi-column chromatography process (176 g L-1 h-1) was calculated for high monoclonal antibody loading concentrations and low loading flow rates. In contrast, the rapid cycling simulated moving bed process achieved the highest productivity (217 g L-1 h-1) for high monoclonal antibody loading concentrations and loading flow rates. Furthermore, due to the higher membrane utilization, the buffer consumption of the rapid cycling simulated moving bed process (1.1 L g-1) was up to 1.9 times lower than that of the batch or rapid cycling parallel multi-column chromatography operation (2.1 L g-1).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Antibodies, MonoclonalMembranes, ArtificialChromatography, AffinityAdsorptionStaphylococcal Protein ADiffusion

Stichwörter der Autor:innen

Affinity chromatographyContinuous chromatographyMembrane chromatographyMonoclonal antibody purificationMulti-column chromatographyProtein A chromatography

Substanzen

Antibodies, MonoclonalMembranes, ArtificialStaphylococcal Protein A

Autor:innen und Institutionen

  • Biothermodynamics, TUM School of Life Sciences, Technical University of Munich, Freising, Germany; Corporate Research, Sartorius Stedim Biotech GmbH, Göttingen, Germany.
  • Biothermodynamics, TUM School of Life Sciences, Technical University of Munich, Freising, Germany.
  • Corporate Research, Sartorius Stedim Biotech GmbH, Göttingen, Germany. Electronic address: markus.kampmann@sartorius.com.

Zitieren

APA

Schmitz, F., Minceva, M., & Kampmann, M. (2024). Comparison of batch and continuous multi-column capture of monoclonal antibodies with convective diffusive membrane adsorbers. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2024.465201

Vancouver

Schmitz F, Minceva M, Kampmann M. Comparison of batch and continuous multi-column capture of monoclonal antibodies with convective diffusive membrane adsorbers. Journal of Chromatography A. 2024. doi:10.1016/j.chroma.2024.465201

BibTeX
@article{Schmitz2024,
  author = {Schmitz, Fabian and Minceva, Mirjana and Kampmann, Markus},
  title = {Comparison of batch and continuous multi-column capture of monoclonal antibodies with convective diffusive membrane adsorbers},
  journal = {Journal of Chromatography A},
  year = {2024},
  doi = {10.1016/j.chroma.2024.465201}
}