EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Separation of weak acids, neutral compounds, and permanent anions using sequential elution liquid chromatography with tandem columns

Lauren Kline Lovejoy, Joe P Foley

Journal of Chromatography A · 2024-08 · 1731 · 465178

DOI: 10.1016/j.chroma.2024.465178 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2024-08. Verfasst von Lauren Kline Lovejoy und 1 weiteren Autor:innen. Beteiligte Einrichtung: R&D Medicine Development and Supply, Analytical Development, GSK, Collegeville, PA 19426, USA; Drexel University, Department of Chemistry, 32 South 3…. Hauptthemen laut MEDLINE: Anions. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper discusses the development of an analytical method by an alternative separation approach, sequential elution liquid chromatography (SE-LC), to separate permanently charged ions (anions), weak acids, and neutral compounds using anion exchange and reversed-phase columns in tandem. SE-LC separates classes of compounds by group by employing two or more elution modes. Advantages to using SE-LC over conventional HPLC are a greater peak capacity and a reduced separation disorder. Importantly, the same HPLC as used for a conventional HPLC separation may be used to afford a successful SE-LC separation. Mobile phase selection and gradient optimization are integral for a successful SE-LC class separation of permanent anions, weak acids, and neutral compounds and will be discussed in detail in this paper. The most successful (best resolution and repeatability) SE-LC separation was achieved by applying isocratic elution at low pH to elute the weak acids, followed by an acetonitrile gradient to elute the neutral compounds, and last a sodium methanesulfonate gradient to elute the anionic compounds using a superficially porous C18 column coupled with a strong anion exchange (SAX) column. Repeatability (RSD) in the retention times and peak areas of the analytes was less than 0.25 % and 1.5 %, respectively.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AnionsChromatography, Ion ExchangeHydrogen-Ion ConcentrationChromatography, High Pressure LiquidAcetonitrilesAcidsReproducibility of ResultsChromatography, LiquidChromatography, Reverse-Phase

Stichwörter der Autor:innen

Anion-exchange chromatographyReversed-phase chromatographySeparation disorderSequential elution liquid chromatographyTandem-column liquid chromatography

Substanzen

AnionsAcetonitrilesAcidsacetonitrile

Autor:innen und Institutionen

  • R&D Medicine Development and Supply, Analytical Development, GSK, Collegeville, PA 19426, USA; Drexel University, Department of Chemistry, 32 South 32nd St., Disque Hall 305, Philadelphia, PA 19104, USA.
  • Drexel University, Department of Chemistry, 32 South 32nd St., Disque Hall 305, Philadelphia, PA 19104, USA. Electronic address: jfoley@drexel.edu.

Zitieren

APA

Lovejoy, L. K., & Foley, J. P. (2024). Separation of weak acids, neutral compounds, and permanent anions using sequential elution liquid chromatography with tandem columns. Journal of Chromatography A, 1731, 465178. https://doi.org/10.1016/j.chroma.2024.465178

Vancouver

Lovejoy LK, Foley JP. Separation of weak acids, neutral compounds, and permanent anions using sequential elution liquid chromatography with tandem columns. Journal of Chromatography A. 2024;1731:465178. doi:10.1016/j.chroma.2024.465178

BibTeX
@article{Lovejoy2024,
  author = {Lovejoy, Lauren Kline and Foley, Joe P},
  title = {Separation of weak acids, neutral compounds, and permanent anions using sequential elution liquid chromatography with tandem columns},
  journal = {Journal of Chromatography A},
  year = {2024},
  volume = {1731},
  pages = {465178},
  doi = {10.1016/j.chroma.2024.465178}
}
Kostenlos starten →