Determination of capsaicin at trace levels in different food, biological and environmental samples by quadruple isotope dilution-gas chromatography mass spectrometry after its preconcentration
Journal of Chromatography A · 2024-08 · 1731 · 465147
DOI: 10.1016/j.chroma.2024.465147 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2024-08. Verfasst von Sezin Erarpat Bodur und 6 weiteren Autor:innen. Beteiligte Einrichtung: Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye. Hauptthemen laut MEDLINE: Gas Chromatography-Mass Spectrometry, Capsaicin, Limit of Detection. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Türkiye Bilimsel ve Teknolojik Araştırma Kurumu.
Abstract (Originalsprache)
Despite the therapeutic properties of capsaicin for some diseases, it shows some side effects for human health. The goal of this study was to develop a precise and accurate analytical strategy for the trace determination of capsaicin in different food, biological and environmental samples including pepper, saliva and wastewater by gas chromatography-mass spectrometry (GC-MS) after spraying-based fine droplet formation-liquid phase microextraction (SFDF-LPME) and quadruple isotope dilution (ID4) method. Acetic anhydride was used as derivatizing agent, and the extraction method was used to enrich the analyte derivative to reach low detection limits. Under the optimum conditions, limit of detection (LOD) and limit of quantitation (LOQ) were determined to be 0.33 and 1.10 µg/kg, respectively. Percent recoveries calculated for SFDF-LPME-GC-MS method ranged between 84.1 and 131.7 %. After the application of ID4-SFDF-LPME-GC-MS method, percent recoveries were obtained in the range of 94.9 and 104.0 % (%RSD ≤ 2.8) for the selected samples. It is obvious that the isotope dilution-based method provided high accurate and precise results due to the elimination of errors during the derivatization, extraction and measurement steps.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye.
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye; İstinye University, Faculty of Pharmacy, Department of Analytical Chemistry, 34010 İstanbul, Türkiye; İstinye University, Scientific and Tec…
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye; Neutec Pharmaceutical, Yıldız Technical University Teknopark, 34220, İstanbul, Türkiye.
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye; Turkish Academy of Sciences (TÜBA), Vedat Dalokay Street, No: 112, 06670, Çankaya, 06670, Ankara, Türkiye. Electronic address: bsezgin@yildi…
Förderung
- Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Zitieren
APA
Bodur, S. E., Bodur, S., Ayyıldız, M. F., Günkara, Ö. T., Dikmen, Y., Doru, E. S., & Bakırdere, S. (2024). Determination of capsaicin at trace levels in different food, biological and environmental samples by quadruple isotope dilution-gas chromatography mass spectrometry after its preconcentration. Journal of Chromatography A, 1731, 465147. https://doi.org/10.1016/j.chroma.2024.465147
Vancouver
Bodur SE, Bodur S, Ayyıldız MF, Günkara ÖT, Dikmen Y, Doru ES, et al. Determination of capsaicin at trace levels in different food, biological and environmental samples by quadruple isotope dilution-gas chromatography mass spectrometry after its preconcentration. Journal of Chromatography A. 2024;1731:465147. doi:10.1016/j.chroma.2024.465147
BibTeX
@article{Bodur2024,
author = {Bodur, Sezin Erarpat and Bodur, Süleyman and Ayyıldız, Merve Fırat and Günkara, Ömer Tahir and Dikmen, Yaren and Doru, Esra Sultan and Bakırdere, Sezgin},
title = {Determination of capsaicin at trace levels in different food, biological and environmental samples by quadruple isotope dilution-gas chromatography mass spectrometry after its preconcentration},
journal = {Journal of Chromatography A},
year = {2024},
volume = {1731},
pages = {465147},
doi = {10.1016/j.chroma.2024.465147}
}
EUVIMED