A simulation-guided approach to the selection of RPLC columns for platform small molecule separations
Journal of Chromatography A · 2024
DOI: 10.1016/j.chroma.2024.465131 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2024. Verfasst von Zhiyang Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Drexel University, 32 South 32nd St., Philadelphia, PA 19104, USA. Hauptthemen laut MEDLINE: Chromatography, Reverse-Phase. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Simulations were conducted to evaluate the potential of several hundred reversed-phase columns to separate small molecules. By calculating the retention factor of compounds in randomly generated virtual mixtures via the HSM (hydrophobic subtraction model) and applying basic chromatography theory, the simulation can estimate the retention time and peak width of every virtual compound and calculate the resolution between every adjacent pair of compounds. A preferred column set based on the number of successful separations of randomly generated virtual mixtures was developed. The tandem-column liquid chromatography (TC-LC) approach can separate 53.2 % of the 16-compound samples using 20 tandem-column pairs, while a single-column approach can only separate 42.6 % of the 16-compound samples with 20 single columns. The preferred set of columns obtained from the simulation was almost the same as the empirical set of columns previously obtained. In screening applications, TC-LC can achieve a comparably successful separation factor (selectivity) with a smaller column inventory (nine 50-mm columns) compared to the larger inventory needed by single-column LC (twenty-one 100-mm columns).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Drexel University, 32 South 32nd St., Philadelphia, PA 19104, USA.
- Bristol Myers Squibb, 1 Squibb Dr, New Brunswick, NJ 08901, USA. Electronic address: jfoley@drexel.edu.
- Bristol Myers Squibb, 1 Squibb Dr, New Brunswick, NJ 08901, USA. Electronic address: jonathan.shackman@bms.com.
Zitieren
APA
Liu, Z., Foley, J. P., Shackman, J. G., Wang, Q., & Zhou, Y. (2024). A simulation-guided approach to the selection of RPLC columns for platform small molecule separations. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2024.465131
Vancouver
Liu Z, Foley JP, Shackman JG, Wang Q, Zhou Y. A simulation-guided approach to the selection of RPLC columns for platform small molecule separations. Journal of Chromatography A. 2024. doi:10.1016/j.chroma.2024.465131
BibTeX
@article{Liu2024,
author = {Liu, Zhiyang and Foley, Joe P and Shackman, Jonathan G and Wang, Qinggang and Zhou, Yiyang},
title = {A simulation-guided approach to the selection of RPLC columns for platform small molecule separations},
journal = {Journal of Chromatography A},
year = {2024},
doi = {10.1016/j.chroma.2024.465131}
}
EUVIMED