EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

In-line fiber optical sensor for detection of IgG aggregates in affinity chromatography

Thuy Tran, Robert Gustavsson, Erik Martinsson, Filip Bergqvist, Andreas Axen, Ingemar Lundström, Carl-Fredrik Mandenius, Daniel Aili

Journal of Chromatography A · 2024

DOI: 10.1016/j.chroma.2024.465129 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2024. Verfasst von Thuy Tran und 7 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Molecular Materials, Division of Biophysics and Bioengineering, Department of Physics, Chemistry and Biology, Linköping University, Lin…. Hauptthemen laut MEDLINE: Immunoglobulin G, Chromatography, Affinity, Surface Plasmon Resonance, Antibodies, Monoclonal. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon 2020, Vinnova, Horizon 2020 Marie Skłodowska-Curie Actions.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Therapeutic monoclonal antibodies (mAbs) are critical for treatment of a wide range of diseases. Immunoglobulin G (IgG) is the most predominant form of mAb but is prone to aggregation during production. Detection and removal of IgG aggregates are time-consuming and laborious. Chromatography is central for purification of biopharmaceuticals in general and essential in the production of mAbs. Protein purification systems are usually equipped with detectors for monitoring pH, UV absorbance, and conductivity, to facilitate optimization and control of the purification process. However, specific in-line detection of the target products and contaminating species, such as aggregates, is currently not possible using convectional techniques. Here we show a novel fiber optical in-line sensor, based on localized surface plasmon resonance (LSPR), for specific detection of IgG and IgG aggregates during affinity chromatography. A flow cell with a Protein A sensor chip was connected to the outlet of the affinity column connected to three different chromatography systems operating at lab scale to pilot scale. Samples containing various IgG concentrations and aggregate contents were analyzed in-line during purification on a Protein A column using both pH gradient and isocratic elution. Because of avidity effects, IgG aggregates showed slower dissociation kinetics than monomers after binding to the sensor chips. Possibilities to detect aggregate concentrations below 1 % and difference in aggregate content smaller than 0.3 % between samples were demonstrated. In-line detection of aggregates can circumvent time-consuming off-line analysis and facilitate automation and process intensification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Immunoglobulin GChromatography, AffinitySurface Plasmon ResonanceAntibodies, MonoclonalStaphylococcal Protein AProtein AggregatesHydrogen-Ion Concentration

Stichwörter der Autor:innen

ChromatographyIgG aggregateIn-line sensorLSPRMonoclonal antibodiesProcess analytical technology

Substanzen

Immunoglobulin GAntibodies, MonoclonalStaphylococcal Protein AProtein Aggregates

Autor:innen und Institutionen

  • Laboratory of Molecular Materials, Division of Biophysics and Bioengineering, Department of Physics, Chemistry and Biology, Linköping University, Linköping 581 83, Sweden; ArgusEye AB, Fridtunagatan 24, Linköping 582 13…
  • Laboratory of Molecular Materials, Division of Biophysics and Bioengineering, Department of Physics, Chemistry and Biology, Linköping University, Linköping 581 83, Sweden.
  • ArgusEye AB, Fridtunagatan 24, Linköping 582 13, Sweden.
  • Cytiva Sweden AB, Björkgatan 30, Uppsala, Sweden.
  • Sensor and Actuator Systems, Department of Physics, Chemistry and Biology, Linköping University, Linköping 581 83, Sweden.
  • Laboratory of Molecular Materials, Division of Biophysics and Bioengineering, Department of Physics, Chemistry and Biology, Linköping University, Linköping 581 83, Sweden. Electronic address: daniel.aili@liu.se.

Förderung

  • Horizon 2020
  • Vinnova
  • Horizon 2020 Marie Skłodowska-Curie Actions

Zitieren

APA

Tran, T., Gustavsson, R., Martinsson, E., Bergqvist, F., Axen, A., Lundström, I., Mandenius, C. F., & Aili, D. (2024). In-line fiber optical sensor for detection of IgG aggregates in affinity chromatography. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2024.465129

Vancouver

Tran T, Gustavsson R, Martinsson E, Bergqvist F, Axen A, Lundström I, et al. In-line fiber optical sensor for detection of IgG aggregates in affinity chromatography. Journal of Chromatography A. 2024. doi:10.1016/j.chroma.2024.465129

BibTeX
@article{Tran2024,
  author = {Tran, Thuy and Gustavsson, Robert and Martinsson, Erik and Bergqvist, Filip and Axen, Andreas and Lundström, Ingemar and Mandenius, Carl-Fredrik and Aili, Daniel},
  title = {In-line fiber optical sensor for detection of IgG aggregates in affinity chromatography},
  journal = {Journal of Chromatography A},
  year = {2024},
  doi = {10.1016/j.chroma.2024.465129}
}
Kostenlos starten →