Magnetic surface-imprinted polymer microspheres coupled with HPLC-MS/MS for sensitive detection of amphetamine-type drugs in water
Journal of Chromatography A · 2024-08 · 1730 · 465097
DOI: 10.1016/j.chroma.2024.465097 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2024-08. Verfasst von Dongqin Tan und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Environmental Science and Engineering, Dalian Maritime University, No.1 Linghai Road, Dalian, 116026, China. Electronic address: tandongqi…. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Water Pollutants, Chemical, Microspheres, Solid Phase Extraction. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China.
Abstract (Originalsprache)
Magnetic surface imprinted polymer microspheres (Fe3O4@MIPs) were successfully synthesized via Pickering emulsion polymerization, utilizing N-Methylphenethylamine as a surrogate template for amphetamine-type drugs. Fe3O4@MIPs not only possessed excellent dispersibility and enough magnetic properties in aqueous solutions, but also displayed good selectivity towards six amphetamines, with an imprinting factor ranging from 1.8 to 2.6. The adsorption kinetics closely aligned with the pseudo-second-order model, and the adsorption efficiency exceeds 80 % for each amphetamine at equilibrium. Fe3O4@MIPs were then employed as the efficient adsorbents for the extraction of amphetamine drugs. Extraction parameters, including sample pH, the mass of adsorbent, and the type and volume of eluting solvent, were carefully optimized. In combination with the high performance liquid chromatography tandem triple quadrupole mass spectrometry (HPLC-MS/MS), a selective magnetic solid-phase extraction (MISPE) method utilizing Fe3O4@MIPs was developed for the detection of six amphetamines in water samples. The limits of detection and limits of quantitation were determined to be 5.2∼23 ng L-1 and 17∼77 ng L-1, respectively. Recoveries for the six target drugs from lake water and sewage samples fell within the range of 87.2∼110 %. Additionally, the MISPE-HPLC-MS/MS method exhibited excellent repeatability, with a precision below 8.5 % at two spiking levels. The prepared Fe3O4@MIPs possessed the advantages of high selectivity, straightforward preparation, facile separation and good reusability, and was highly suitable for the efficient extraction of amphetamine-type substances in complex environmental water.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Environmental Science and Engineering, Dalian Maritime University, No.1 Linghai Road, Dalian, 116026, China. Electronic address: tandongqin@dlmu.edu.cn.
- College of Environmental Science and Engineering, Dalian Maritime University, No.1 Linghai Road, Dalian, 116026, China.
- Key Laboratory of Separation Sciences for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, 116023, China.
- Department of Chemistry, Lishui University, Lishui, 32300, China.
- Department of Chemistry, University of Allahabad, India.
Förderung
- Fundamental Research Funds for the Central Universities
- National Natural Science Foundation of China
Zitieren
APA
Tan, D., Wang, Y., Fan, H., Jin, J., Sun, X., Dhanjai, & Wang, D. (2024). Magnetic surface-imprinted polymer microspheres coupled with HPLC-MS/MS for sensitive detection of amphetamine-type drugs in water. Journal of Chromatography A, 1730, 465097. https://doi.org/10.1016/j.chroma.2024.465097
Vancouver
Tan D, Wang Y, Fan H, Jin J, Sun X, Dhanjai, et al. Magnetic surface-imprinted polymer microspheres coupled with HPLC-MS/MS for sensitive detection of amphetamine-type drugs in water. Journal of Chromatography A. 2024;1730:465097. doi:10.1016/j.chroma.2024.465097
BibTeX
@article{Tan2024,
author = {Tan, Dongqin and Wang, Yue and Fan, Haocheng and Jin, Jing and Sun, Xiaoli and Dhanjai and Wang, Degao},
title = {Magnetic surface-imprinted polymer microspheres coupled with HPLC-MS/MS for sensitive detection of amphetamine-type drugs in water},
journal = {Journal of Chromatography A},
year = {2024},
volume = {1730},
pages = {465097},
doi = {10.1016/j.chroma.2024.465097}
}