Analysis of 15 bile acids in human plasma based on C18 functionalized magnetic organic polymer nanocomposite coupled with liquid chromatography-tandem mass spectrometry
Journal of Chromatography A · 2024-06 · 1725 · 464962
DOI: 10.1016/j.chroma.2024.464962 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2024-06. Verfasst von Shun Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Ningbo No.2 Hospital, Ningbo 315010, China; Guoke Ningbo Life Science and Health Industry Research Institute, Ningbo 315010, China; Key Laboratory of…. Hauptthemen laut MEDLINE: Bile Acids and Salts, Tandem Mass Spectrometry, Nanocomposites, Limit of Detection. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
Because of the "enterohepatic circulation" of bile acid, liver damage can be reflected by monitoring the content of bile acid in the serum of the organism. To monitor the concentration of 15 bile acids in plasma samples, a new technique of PRiME (process, ruggedness, improvement, matrix effect, ease of use) pass-through cleanup procedure combined with high performance liquid chromatography-tandem quadrupole mass spectrometry (HPLC-MS/MS) was developed. The sorbent used in the PRiME pass-through cleanup procedure is a new type of magnetic organic resin composite nano-material modified by C18 (C18-PS-DVB-GMA-Fe3O4), which has high cleanup efficiency of plasma samples. It also shows good performance in the separation and analysis of 15 kinds of bile acids. Under the optimal conditions, the results show higher cleanup efficiency of C18-PS-DVB-GMA-Fe3O4 with recoveries in the range of 82.1-115 %. The limit of quantitative (LOQs) of 15 bile acids were in the range of 0.033 µg/L-0.19 µg/L, and the RSD values of 15 bile acids were in the range of 3.00-11.9 %. Validation results on linearity, specificity, accuracy and precision, as well as on the application to analysis of 15 bile acids in 100 human plasma samples demonstrate the applicability to clinical studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Ningbo No.2 Hospital, Ningbo 315010, China; Guoke Ningbo Life Science and Health Industry Research Institute, Ningbo 315010, China; Key Laboratory of Diagnosis and Treatment of Digestive System Tumors of Zhejiang Provin…
- College of Biological and Environmental Engineering, Zhejiang Shuren University, Hangzhou 310015, China. Electronic address: 11637067@zju.edu.cn.
- Jiaxing Center for Disease Control and Prevention, Jiaxing 314050, China. Electronic address: caominyi@zju.edu.cn.
Zitieren
APA
Zhang, S., Cai, T., Lin, J., Liu, J. J., Zhao, Y. G., & Cao, M. Y. (2024). Analysis of 15 bile acids in human plasma based on C18 functionalized magnetic organic polymer nanocomposite coupled with liquid chromatography-tandem mass spectrometry. Journal of Chromatography A, 1725, 464962. https://doi.org/10.1016/j.chroma.2024.464962
Vancouver
Zhang S, Cai T, Lin J, Liu JJ, Zhao YG, Cao MY. Analysis of 15 bile acids in human plasma based on C18 functionalized magnetic organic polymer nanocomposite coupled with liquid chromatography-tandem mass spectrometry. Journal of Chromatography A. 2024;1725:464962. doi:10.1016/j.chroma.2024.464962
BibTeX
@article{Zhang2024,
author = {Zhang, Shun and Cai, Ting and Lin, Jing and Liu, Jia-Juan and Zhao, Yong-Gang and Cao, Min-Yi},
title = {Analysis of 15 bile acids in human plasma based on C18 functionalized magnetic organic polymer nanocomposite coupled with liquid chromatography-tandem mass spectrometry},
journal = {Journal of Chromatography A},
year = {2024},
volume = {1725},
pages = {464962},
doi = {10.1016/j.chroma.2024.464962}
}