Fabrication and application of a continuously regenerated cationic impurity removal device for ion chromatography
Journal of Chromatography A · 2024
DOI: 10.1016/j.chroma.2024.464904 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2024. Verfasst von Yihua Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Engineering Research Center of Pharmaceutical Process Chemistry, Shanghai Frontiers Science Center of Optogenetic Techniques for Cell Metabolism, Eas…. Hauptthemen laut MEDLINE: Cations. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
A continuously regenerated cationic impurity removal device (CR-CRD) has been fabricated and applied for ion chromatography (IC). The removal of cationic impurities is realized by electrodialytically replacing the cationic impurities with hydronium ions. The device is configured in a sandwich structure and the central eluent channel is respectively isolated from both electrodes by stacked cation exchange membranes and a bipolar membrane (BPM) plus stacked anion exchange membranes. The eluent channel is packed with cation exchange resins in hydronium form and their continuous regeneration can be achieved by electrodialysis. A desirable feature of the device is gas-free, and no degasser is required. It showed sufficient ability to remove cationic impurities, as indicated by > 99.9 % removal of 10 mL of 1 mM LiOH solution injected (∼10 μmol) or continuous removal of 1 mM LiOH solution at the flow rate of 1 mL/min (1 μmol/min). A useful application was for sample pretreatment in nuclear power industry, by eliminating strong matrix interference of the sample containing LiOH (1 mM) and boric acid (2000 mg/L) with trace anion analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Engineering Research Center of Pharmaceutical Process Chemistry, Shanghai Frontiers Science Center of Optogenetic Techniques for Cell Metabolism, East China University of Science and Technology, Shanghai 200237, China.
- Engineering Research Center of Pharmaceutical Process Chemistry, Shanghai Frontiers Science Center of Optogenetic Techniques for Cell Metabolism, East China University of Science and Technology, Shanghai 200237, China.…
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Li, Y., Zhang, T., Zhang, F., Chen, W., & Yang, B. (2024). Fabrication and application of a continuously regenerated cationic impurity removal device for ion chromatography. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2024.464904
Vancouver
Li Y, Zhang T, Zhang F, Chen W, Yang B. Fabrication and application of a continuously regenerated cationic impurity removal device for ion chromatography. Journal of Chromatography A. 2024. doi:10.1016/j.chroma.2024.464904
BibTeX
@article{Li2024,
author = {Li, Yihua and Zhang, Tianyang and Zhang, Feifang and Chen, Weiqing and Yang, Bingcheng},
title = {Fabrication and application of a continuously regenerated cationic impurity removal device for ion chromatography},
journal = {Journal of Chromatography A},
year = {2024},
doi = {10.1016/j.chroma.2024.464904}
}
EUVIMED