Adjustable chromatographic performance of silica-based mixed-mode stationary phase through the control of co-grafting amounts of imidazole and C18 chain
Journal of Chromatography A · 2024
DOI: 10.1016/j.chroma.2024.464889 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2024. Verfasst von Yali Yang und 6 weiteren Autor:innen. Beteiligte Einrichtung: CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemi…. Hauptthemen laut MEDLINE: Imidazoles, Silicon Dioxide, Chromatography, Reverse-Phase, Polycyclic Aromatic Hydrocarbons. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 48 Literaturangaben.
Abstract (Originalsprache)
In this paper, three imidazole- and C18- bifunctional silica stationary phases (Sil-Im-C18) were prepared by adjusting introduction interval of octadecyltrichlorosilane (ODS) and 3-imidazol-1-ylpropyl(trimethoxy)silane (TMPImS), which can be used for reversed-phase liquid chromatography (RPLC) and ion exchange chromatography (IEC) with adjustable performance. The successful preparation of Sil-Im-C18 were confirmed by the characterizations of elemental analysis, infrared spectroscopy (FTIR) and contact angle (CA). Chromatographic performance of Sil-Im-C18 were evaluated by the separation of Tanaka test mixture, alkylbenzenes, linear PAHs and a set of analytes with different properties (uracil, phenol, 1,2-dinitrobenzene and naphthalene), and compared with commonly used C18 column. It was found that the chromatographic performance of Sil-Im-C18 changed significantly with the difference in bonding amount of imidazole and C18. Sil-Im-C18 demonstrated the excellent separation performance towards polycyclic aromatic hydrocarbons (PAHs), phenylesters, phenylamines, phenols and inorganic anions, and notably, nucleobases and nucleosides can be separated using pure water as mobile phases. The van Deemter plot showed that the column efficiency of Sil-Im-C18-3 was 64,933 plate·m-1 for naphthalene, indicated that Sil-Im-C18 was reasonably chromatographic columns. The RSD values of retention time were 0.22 %-0.61 % for 10 needles alkylbenzenes injected continuously at 50 °C to investigate thermal stability and repeatability, all the fluctuations of k of naphthalene were less than 2.3 % for Sil-Im-C18-1 during flushing 24 h with the mobile phase at different pH values (pH = 3 and 8), the retention time of alkylbenzenes were almost same for Sil-Im-C18-1 at different time, the RSD values of retention time of alkylbenzenes were 0.45 %-2.28 % for two batches Sil-Im-C18-1, revealing the excellent repeatability, thermal stability, durability and reproducibility of Sil-Im-C18, and implying a commercial prospect.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China; Key L…
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China. Elect…
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China.
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou 730070, China. Electronic address: liuxh@nwnu.edu.cn.
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, China; Ganji…
Zitieren
APA
Yang, Y., Chen, J., Liang, X., Liu, B., Quan, K., Liu, X., & Qiu, H. (2024). Adjustable chromatographic performance of silica-based mixed-mode stationary phase through the control of co-grafting amounts of imidazole and C18 chain. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2024.464889
Vancouver
Yang Y, Chen J, Liang X, Liu B, Quan K, Liu X, et al. Adjustable chromatographic performance of silica-based mixed-mode stationary phase through the control of co-grafting amounts of imidazole and C18 chain. Journal of Chromatography A. 2024. doi:10.1016/j.chroma.2024.464889
BibTeX
@article{Yang2024,
author = {Yang, Yali and Chen, Jia and Liang, Xiaojing and Liu, Bei and Quan, Kaijun and Liu, Xiuhui and Qiu, Hongdeng},
title = {Adjustable chromatographic performance of silica-based mixed-mode stationary phase through the control of co-grafting amounts of imidazole and C18 chain},
journal = {Journal of Chromatography A},
year = {2024},
doi = {10.1016/j.chroma.2024.464889}
}
EUVIMED