EUVIMEDEUVIMED entdecken
Crossref

Adeno-associated virus analysis by size exclusion chromatography within 3 minutes using short bio-inert columns made with 3 µm particles operated at high flowrates

James Y Song, Tivadar Farkas

Journal of Chromatography A · 2024

DOI: 10.1016/j.chroma.2024.464684 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2024. Verfasst von James Y Song und 1 weiteren Autor:innen. Beteiligte Einrichtung: Phenomenex Inc., 411 Madrid Avenue, Torrance, CA 90501, USA. Hauptthemen laut MEDLINE: Dependovirus, Proteins. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Adeno-associated virus (AAV) analytical characterization is crucial to the well-defined and reproducible production of human gene therapies utilizing the AAV vector modality. The establishment of analytical methods based upon technology platforms currently widely used by bio-therapeutic manufacturers, namely HPLC, will assist efforts to produce high quality AAV reproducibly and decrease chemical manufacturing and control challenges in method portability and reliability. AAV analysis by size exclusion chromatography (SEC) is currently practiced with columns and mobile phase conditions traditional to SEC of proteins. Here, an improved method to measure multiple AVV critical quality attributes (CQA) rapidly by SEC is explored. The use of short columns made with small particles at high flow rates resulted in up to 80 % reduction in analysis time and 66 % in sample consumption while maintaining reliable quantitation of AAV aggregate or high molecular weight (HMW) content. These results were demonstrated across four different AAV serotypes. Furthermore, critical AAV sample handling learnings are shared.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DependovirusProteinsHumansReproducibility of ResultsChromatography, GelChromatography, High Pressure LiquidGenetic Vectors

Stichwörter der Autor:innen

Adeno-associated virusAggregate quantitationSample handlingSize exclusion chromatography

Substanzen

Proteins

Autor:innen und Institutionen

  • Phenomenex Inc., 411 Madrid Avenue, Torrance, CA 90501, USA.
  • Phenomenex Inc., 411 Madrid Avenue, Torrance, CA 90501, USA. Electronic address: jamess@phenomenex.com.

Zitieren

APA

Song, J. Y., & Farkas, T. (2024). Adeno-associated virus analysis by size exclusion chromatography within 3 minutes using short bio-inert columns made with 3 µm particles operated at high flowrates. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2024.464684

Vancouver

Song JY, Farkas T. Adeno-associated virus analysis by size exclusion chromatography within 3 minutes using short bio-inert columns made with 3 µm particles operated at high flowrates. Journal of Chromatography A. 2024. doi:10.1016/j.chroma.2024.464684

BibTeX
@article{Song2024,
  author = {Song, James Y and Farkas, Tivadar},
  title = {Adeno-associated virus analysis by size exclusion chromatography within 3 minutes using short bio-inert columns made with 3 µm particles operated at high flowrates},
  journal = {Journal of Chromatography A},
  year = {2024},
  doi = {10.1016/j.chroma.2024.464684}
}
Kostenlos starten →