Dual optical detection approach for capillary electrophoresis following two-step liquid-liquid extraction to determine ten phenols in water samples
Journal of Chromatography A · 2024
DOI: 10.1016/j.chroma.2023.464609 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2024. Verfasst von Manh Huy Nguyen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Analytical Technology for Environmental Quality and Food Safety Control (KLATEFOS), VNU University of Science (VNU-HUS), Vietnam Na…. Hauptthemen laut MEDLINE: Phenols, Water Pollutants, Chemical. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Đại học Quốc gia Hà Nội, Vietnam National University Hanoi.
Abstract (Originalsprache)
In this research, the analytical method was developed and evaluated for determining phenol and its nine derivatives belong to the US EPA priority pollutant list in water samples by using dual-channeled capillary electrophoresis (CE) coupled with two types of optical detectors, namely LED-induced fluorescence (LEDIF) and ultraviolet (UV) detectors. The optimal background electrolytes for the first and second CE channels were 20 mM borate (pH 9.80) with 400 µM fluorescein and 55 mM borate (pH 11.75), respectively. The two-step liquid-liquid extraction (LLE) was used for sample preparation and enrichment, in which phenol and its derivatives were extracted from the aqueous phase using 10 mL of n-hexane/1-octanol (60/40, v/v) and then were back extracted into a 0.1 M NaOH as a final acceptor phase. Under the optimal CE and two-step LLE conditions, the enrichment factors of 10 phenols were 184 - 1120-fold, and the method detection limits were lowered to 0.02-0.60 µg/L. The obtained intra-day and inter-day precisions in terms of relative standard deviations (RSD) were between 4.0 and 7.3 % and 6.7 and 14 %, respectively. This approach was used to determine phenols in water samples, with recoveries ranging from 82.0 to 108.9 %. In combination with sample enrichment by two-step LLE extraction, this is the first CE study conducted to determine phenols in the EPA list using two detector approaches, specifically CE-LEDIF/CE-UV.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Analytical Technology for Environmental Quality and Food Safety Control (KLATEFOS), VNU University of Science (VNU-HUS), Vietnam National University, Hanoi (VNU), 334 Nguyen Trai Street, Thanh Xuan Dis…
Förderung
- Đại học Quốc gia Hà Nội
- Vietnam National University Hanoi
Zitieren
APA
Nguyen, M. H., Nguyen, T. D., Duong, H. A., & Pham, H. V. (2024). Dual optical detection approach for capillary electrophoresis following two-step liquid-liquid extraction to determine ten phenols in water samples. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2023.464609
Vancouver
Nguyen MH, Nguyen TD, Duong HA, Pham HV. Dual optical detection approach for capillary electrophoresis following two-step liquid-liquid extraction to determine ten phenols in water samples. Journal of Chromatography A. 2024. doi:10.1016/j.chroma.2023.464609
BibTeX
@article{Nguyen2024,
author = {Nguyen, Manh Huy and Nguyen, Thanh Dam and Duong, Hong Anh and Pham, Hung Viet},
title = {Dual optical detection approach for capillary electrophoresis following two-step liquid-liquid extraction to determine ten phenols in water samples},
journal = {Journal of Chromatography A},
year = {2024},
doi = {10.1016/j.chroma.2023.464609}
}
EUVIMED