EUVIMEDEUVIMED entdecken
Crossref

Open tubular capillary electrochromatography with dual-responsive polymer as coating for separation of chromones

Nasir Ali, Fuyi Wang, Li Qi

Journal of Chromatography A · 2024

DOI: 10.1016/j.chroma.2023.464595 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2024. Verfasst von Nasir Ali und 2 weiteren Autor:innen. Beteiligte Einrichtung: Beijing National Laboratory of Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Acad…. Hauptthemen laut MEDLINE: Polymers, Capillary Electrochromatography. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fabricating polymeric coatings that are responsive to multiple/dual stimuli is crucial and remains a major challenge in the development of highly efficient open tubular capillary electrochromatography (OT-CEC). In this study, a pH and temperature-responsive block copolymer, poly(styrene-maleic anhydride 2-dimethylamino ethyl methacrylate), P(St-MAn-DMAEMA), was designed and synthesized. Using P(St-MAn-DMAEMA) as the coating, an OT-CEC protocol was constructed for the analysis of chromones. The morphology and hydrophobicity-hydrophilicity of the polymeric coating could change via varying the environmental conditions, affecting the separation efficiency of OT-CEC. Interestingly, the best performance of OT-CEC was achieved at pH 9.7 and 45 °C via tuning the interactions between the coating and the analytes. Additionally, the proposed OT-CEC method exhibited a good linear range for the detection of the three test chromones from 10.0 to 100.0 μM, with all correlation coefficients (R2) >0.997. The coatings also had good stability and reusability. This work provides an approach for the preparation of new multiple-stimuli-responsive polymeric coatings for the establishment of OT-CEC systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PolymersCapillary ElectrochromatographyHumansMethacrylatesNylons

Stichwörter der Autor:innen

ChromonesDual-responsive block copolymerHydrophobicity-hydrophilicityOpen tubular capillary electrochromatographySeparation efficiency

Substanzen

PolymersMethacrylates2-(dimethylamino)ethyl methacrylatepoly(2-(dimethylamino)ethyl methacrylate)Nylons

Autor:innen und Institutionen

  • Beijing National Laboratory of Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, No. 2 Zhongguancun Beiyijie, Beijing 100190, China; U…

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Ali, N., Wang, F., & Qi, L. (2024). Open tubular capillary electrochromatography with dual-responsive polymer as coating for separation of chromones. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2023.464595

Vancouver

Ali N, Wang F, Qi L. Open tubular capillary electrochromatography with dual-responsive polymer as coating for separation of chromones. Journal of Chromatography A. 2024. doi:10.1016/j.chroma.2023.464595

BibTeX
@article{Ali2024,
  author = {Ali, Nasir and Wang, Fuyi and Qi, Li},
  title = {Open tubular capillary electrochromatography with dual-responsive polymer as coating for separation of chromones},
  journal = {Journal of Chromatography A},
  year = {2024},
  doi = {10.1016/j.chroma.2023.464595}
}
Kostenlos starten →