Validating blood microsampling for per- and polyfluoroalkyl substances quantification in whole blood
Journal of Chromatography A · 2024
DOI: 10.1016/j.chroma.2023.464522 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2024. Verfasst von Jordan M Partington und 6 weiteren Autor:innen. Beteiligte Einrichtung: Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria 3010, Australia; Trajan Scientific and Medica…. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Fluorocarbons. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Research Council, Agilent Technologies.
Abstract (Originalsprache)
Microsampling allows the collection of blood samples using a method which is inexpensive, simple and minimally-invasive, without the need for specially-trained medical staff. Analysis of whole blood provides a more holistic understanding of per- and polyfluoroalkyl substances (PFAS) body burden. Capillary action microsamplers (Trajan hemaPEN®) allow the controlled collection of whole blood as dried blood spots (DBS) (four 2.74 µL ± 5 %). The quantification of 75 PFAS from DBS was evaluated by comparing five common extraction techniques. Spiked blood (5 ng/mL PFAS) was extracted by protein precipitation (centrifuged; filtered), acid-base liquid-liquid extraction, trypsin protease digestion, and weak anion exchange (WAX) solid-phase extraction with analysis by high-performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Filtered protein precipitation was the most effective extraction method, recovering 72 of the 75 PFAS within 70 to 130 % with method reporting limit (MRL) for PFOS of 0.17 ng/L and ranging between 0.05 ng/mL and 0.34 ng/mL for all other PFAS. The optimised method was applied to human blood samples to examine Inter- (n = 7) and intra-day (n = 5) PFAS blood levels in one individual. Sixteen PFAS were detected with an overall Σ16PFAS mean = 6.3 (range = 5.7-7.0) ng/mL and perfluorooctane sulfonate (branched and linear isomers, ΣPFOS) = 3.3 (2.8-3.7) ng/mL being the dominant PFAS present. To the authors knowledge, this minimally invasive self-sampling protocol is the most extensive method for PFAS in blood reported and could be a useful tool for large scale human biomonitoring studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria 3010, Australia; Trajan Scientific and Medical, Ringwood, Victoria 3134, Australia.
- Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria 3010, Australia.
- Department of Materials and Environmental Chemistry, Stockholm University, Stockholm SE11418, Sweden.
- Trajan Scientific and Medical, Ringwood, Victoria 3134, Australia.
- Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria 3010, Australia. Electronic address: brad.clarke@unimelb.edu.au.
Förderung
- Australian Research Council
- Agilent Technologies
Zitieren
APA
Partington, J. M., Marchiandi, J., Szabo, D., Gooley, A., Kouremenos, K., Smith, F., & Clarke, B. O. (2024). Validating blood microsampling for per- and polyfluoroalkyl substances quantification in whole blood. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2023.464522
Vancouver
Partington JM, Marchiandi J, Szabo D, Gooley A, Kouremenos K, Smith F, et al. Validating blood microsampling for per- and polyfluoroalkyl substances quantification in whole blood. Journal of Chromatography A. 2024. doi:10.1016/j.chroma.2023.464522
BibTeX
@article{Partington2024,
author = {Partington, Jordan M and Marchiandi, Jaye and Szabo, Drew and Gooley, Andrew and Kouremenos, Konstantinos and Smith, Fraser and Clarke, Bradley O},
title = {Validating blood microsampling for per- and polyfluoroalkyl substances quantification in whole blood},
journal = {Journal of Chromatography A},
year = {2024},
doi = {10.1016/j.chroma.2023.464522}
}
EUVIMED