A green deep eutectic solvent based dispersive liquid-liquid microextraction for the quantitative analysis of 21 polychlorinated biphenyl metabolites in food of animal origin using injector port silylation-gas chromatography-tandem mass spectrometry
Journal of Chromatography A · 2023
DOI: 10.1016/j.chroma.2023.464338 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2023. Verfasst von Sireesha Ganneru und 2 weiteren Autor:innen. Beteiligte Einrichtung: Analytical and Structural Chemistry Department, CSIR-Indian Institute of Chemical Technology, Tarnaka, Hyderabad, 500007, India. Hauptthemen laut MEDLINE: Polychlorinated Biphenyls, Liquid Phase Microextraction. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Council of Scientific and Industrial Research, India.
Abstract (Originalsprache)
An analytical method was developed for the quantitative determination of 21 polychlorinated biphenyls (PCBs) metabolites (17 were -OH, 1 -MeO, and 3 were MeSO2) in foods of animal origin using deep eutectic solvent (DES) based dispersive liquid-liquid microextraction followed by injector port silylation-gas chromatography-tandem mass spectrometry. The type of DES (thymol: camphor, 1:1 molar ratio) and optimum volume of DES (300 µL), pH (7.0), and disperser solvent (acetonitrile) were optimized to attain the maximum extraction efficiency. The limit of detection, limit of quantification, and percent recovery were found to be in the range of 0.12-0.23 ng/mL, 0.40-0.76 ng/mL, and 80.1-111.4%, respectively. The expanded uncertainty was observed to be in the range of 7.2-22.8% for the targeted analytes. The proposed method was applied to real food samples (milk, meat, fish, and egg) and the levels were found to be in the range of 0.64-32.14 ng/g. This is first of its kind method using green solvent based method for the analysis of PCB metabolites (-OH, MeO, and MeSO2) and will find extensive application in routine testing for foods of animal origin.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Analytical and Structural Chemistry Department, CSIR-Indian Institute of Chemical Technology, Tarnaka, Hyderabad, 500007, India.
- Analytical and Structural Chemistry Department, CSIR-Indian Institute of Chemical Technology, Tarnaka, Hyderabad, 500007, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India.
- Analytical and Structural Chemistry Department, CSIR-Indian Institute of Chemical Technology, Tarnaka, Hyderabad, 500007, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India; Analytica…
Förderung
- Council of Scientific and Industrial Research, India
Zitieren
APA
Ganneru, S., Seetha, B. S., & Mudiam, M. K. R. (2023). A green deep eutectic solvent based dispersive liquid-liquid microextraction for the quantitative analysis of 21 polychlorinated biphenyl metabolites in food of animal origin using injector port silylation-gas chromatography-tandem mass spectrometry. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2023.464338
Vancouver
Ganneru S, Seetha BS, Mudiam MKR. A green deep eutectic solvent based dispersive liquid-liquid microextraction for the quantitative analysis of 21 polychlorinated biphenyl metabolites in food of animal origin using injector port silylation-gas chromatography-tandem mass spectrometry. Journal of Chromatography A. 2023. doi:10.1016/j.chroma.2023.464338
BibTeX
@article{Ganneru2023,
author = {Ganneru, Sireesha and Seetha, Bala Subrahanyam and Mudiam, Mohana Krishna Reddy},
title = {A green deep eutectic solvent based dispersive liquid-liquid microextraction for the quantitative analysis of 21 polychlorinated biphenyl metabolites in food of animal origin using injector port silylation-gas chromatography-tandem mass spectrometry},
journal = {Journal of Chromatography A},
year = {2023},
doi = {10.1016/j.chroma.2023.464338}
}
EUVIMED