EUVIMEDEUVIMED entdecken
Crossref

Impact of structural similarity on the accuracy of retention time prediction

Roman Szucs, Roland Brown, Claudio Brunelli, Jasna Hradski, Marián Masár

Journal of Chromatography A · 2023-09 · 1707 · 464317

DOI: 10.1016/j.chroma.2023.464317 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2023-09. Verfasst von Roman Szucs und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University Bratislava, Ilkovičova 6, SK-84215 Bratislava, Slovakia. Electro…. Hauptthemen laut MEDLINE: Algorithms, Structure-Activity Relationship. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Vedecká Grantová Agentúra MŠVVaŠ SR a SAV, APVV.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitative Structure-Retention Relationships offer a valuable tool for de-risking chromatographic methods in relation to newly formed or hypothetical compounds, arising from synthetic processes or formulation activities. They can also be used to identify optimal separation conditions, or in support of structural elucidation. In this contribution, we provide a systematic study of the relationship between the accuracy of the retention model, the size of the training set and its structural similarity to the predicted compound. We compare structural similarity expressed either on a fingerprint basis (e.g., Tanimoto index), or by Euclidean distance calculated from of subset of molecular descriptors. The results presented indicate that accurate and predictive models can be built from a small dataset containing as few as 25 compounds, provided that the training set is structurally similar to the test compound. When the training set contains compounds selected by minimizing the Euclidean distance calculated from 3 descriptors most correlated with the retention time, root mean square error of 0.48 min and correlation coefficient of 0.9464 were observed for the test sets of 104 compounds. Moreover, these models meet the Tropsha predictivity criteria. These findings potentially bring the prediction of retention times within the practical reach of pharmaceutical analysts involved in chromatographic method development. We also present an optimisation approach to select algorithm settings in order to minimize the prediction error and ensure model predictivity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsStructure-Activity Relationship

Stichwörter der Autor:innen

Quantitative structure-retention relationshipsRetention time predictionStructural similarity

Autor:innen und Institutionen

  • Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University Bratislava, Ilkovičova 6, SK-84215 Bratislava, Slovakia. Electronic address: roman.szucs@uniba.sk.
  • Pfizer R&D UK Limited, Ramsgate Road, Sandwich CT13 9NJ, UK.
  • Department of Analytical Chemistry, Faculty of Natural Sciences, Comenius University Bratislava, Ilkovičova 6, SK-84215 Bratislava, Slovakia.

Förderung

  • Vedecká Grantová Agentúra MŠVVaŠ SR a SAV
  • APVV

Zitieren

APA

Szucs, R., Brown, R., Brunelli, C., Hradski, J., & Masár, M. (2023). Impact of structural similarity on the accuracy of retention time prediction. Journal of Chromatography A, 1707, 464317. https://doi.org/10.1016/j.chroma.2023.464317

Vancouver

Szucs R, Brown R, Brunelli C, Hradski J, Masár M. Impact of structural similarity on the accuracy of retention time prediction. Journal of Chromatography A. 2023;1707:464317. doi:10.1016/j.chroma.2023.464317

BibTeX
@article{Szucs2023,
  author = {Szucs, Roman and Brown, Roland and Brunelli, Claudio and Hradski, Jasna and Masár, Marián},
  title = {Impact of structural similarity on the accuracy of retention time prediction},
  journal = {Journal of Chromatography A},
  year = {2023},
  volume = {1707},
  pages = {464317},
  doi = {10.1016/j.chroma.2023.464317}
}
Kostenlos starten →