EUVIMEDEUVIMED entdecken
Crossref

Micellar enhanced chromatographic separation of selected hazardous chemical present in hair dye and their detection in formulations and swab, including assessment of damage caused to cuticle of hair shaft

Priyanka Pahade, Abhilasha Durgbanshi, Samuel Carda-Broch, Juan Peris-Vicente, Devasish Bose

Journal of Chromatography A · 2023

DOI: 10.1016/j.chroma.2023.464206 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2023. Verfasst von Priyanka Pahade und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Criminology and Forensic Science, Doctor Harisingh Gour Vishwavidyalaya (A Central University), Sagar, Madhya Pradesh 470003, India. Hauptthemen laut MEDLINE: Hair Dyes. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: University Grants Commission, Universitat Jaume I, Department of Science and Technology, Ministry of Science and Technology, India.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hydroquinone (HQ), resorcinol (RS), m-aminophenol (m-AMP) and p-phenylenediamine (p-PPD) are aromatic compounds which are generally used in hair dyes to provide different colours to hair. In European Union the concentrations of HQ, RS, m-AMP and p-PPD is regulated in hair dyes and other cosmetic products by EU commission regulation EU/2019/831. This legislation is generally exercised because all these compounds are toxic and may cause severe allergies when used regularly. However in India no such regulations exist to monitor these toxic compounds in hair dyes therefore in this study a simple, rapid, economical and ecofriendly micellar liquid chromatographic (MLC) technique has been developed which can monitor all the selected toxic compounds simultaneously. HQ and RS are positional isomers and are difficult to be separated by HPLC whereas with the developed MLC method it was well separated and detected. The developed MLC technique has been applied to detect and quantify selected analytes in oxidative and non-oxidative hair dyes and swab samples from the scalp. The simultaneous separation of selected analytes was performed in mobile phase 0.09 M SDS, 0.01 M NaH2PO4-2% v/v 1-butanol at pH 7 running through C18 column under isocratic mode at 1 mL/min. flow rate. All the analytes were eluted within 6 min. The present method has been validated following the EURCHEM Guideline, 2014 in terms of calibration range (0.08-15 µg/mL), limit of detection (0.01-0.09 µg/mL), limit of quantification (0.08-0.35 µg/mL), accuracy (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hair DyesMicellesChromatography, LiquidChromatography, High Pressure LiquidHairAminophenolsHydroquinonesResorcinolsPhenylenediamines

Stichwörter der Autor:innen

HairHair dyesMicellar liquid chromatographyScanning Electron Microscope

Substanzen

Hair DyesMicelles3-aminophenolAminophenolshydroquinoneHydroquinonesresorcinolResorcinols4-phenylenediaminePhenylenediamines

Autor:innen und Institutionen

  • Department of Criminology and Forensic Science, Doctor Harisingh Gour Vishwavidyalaya (A Central University), Sagar, Madhya Pradesh 470003, India.
  • Department of Chemistry, Doctor Harisingh Gour Vishwavidyalaya (A Central University), Sagar, Madhya Pradesh 470003, India.
  • Bioanalytical Chemistry, Department of Physical and Analytical Chemistry, ESTCE, Universitat Jaume I, Castello 12071, Spain.
  • Department of Analytical Chemistry, Faculty of Chemistry, Universitat de València, Burjassot-Valencia 46100, Spain.
  • Department of Criminology and Forensic Science, Doctor Harisingh Gour Vishwavidyalaya (A Central University), Sagar, Madhya Pradesh 470003, India. Electronic address: dbose@dhsgsu.edu.in.

Förderung

  • University Grants Commission
  • Universitat Jaume I
  • Department of Science and Technology, Ministry of Science and Technology, India

Zitieren

APA

Pahade, P., Durgbanshi, A., Carda-Broch, S., Peris-Vicente, J., & Bose, D. (2023). Micellar enhanced chromatographic separation of selected hazardous chemical present in hair dye and their detection in formulations and swab, including assessment of damage caused to cuticle of hair shaft. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2023.464206

Vancouver

Pahade P, Durgbanshi A, Carda-Broch S, Peris-Vicente J, Bose D. Micellar enhanced chromatographic separation of selected hazardous chemical present in hair dye and their detection in formulations and swab, including assessment of damage caused to cuticle of hair shaft. Journal of Chromatography A. 2023. doi:10.1016/j.chroma.2023.464206

BibTeX
@article{Pahade2023,
  author = {Pahade, Priyanka and Durgbanshi, Abhilasha and Carda-Broch, Samuel and Peris-Vicente, Juan and Bose, Devasish},
  title = {Micellar enhanced chromatographic separation of selected hazardous chemical present in hair dye and their detection in formulations and swab, including assessment of damage caused to cuticle of hair shaft},
  journal = {Journal of Chromatography A},
  year = {2023},
  doi = {10.1016/j.chroma.2023.464206}
}
Kostenlos starten →