In-situ immobilization of covalent organic frameworks as stationary phase for capillary electrochromatography
Journal of Chromatography A · 2023
DOI: 10.1016/j.chroma.2023.464205 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2023. Verfasst von Yuanyuan Fu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, School of Pharmaceutical Sciences, Wuhan University, Wuhan …. Hauptthemen laut MEDLINE: Metal-Organic Frameworks, Capillary Electrochromatography. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
A new kind of covalent organic framework (COF) was first utilized as an stationary phase for open-tubular electrochromatography (OT-CEC) by in situ synthesis immobilized method at room temperature. On the basis of our previous work, 4,4',4″-(1,3,5-Triazine-2,4,6-triyl)trianiline (TZ) and 2,5-bis(2-propyn-1-yloxy)-1,4-benzenedicarboxaldehyde (BPTA) were employed as building blocks for the synthesis of COF TZ-BPTA. The coated capillary and COF TZ-BPTA were characterized by scanning electron microscopy (SEM). Then, Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction (XRD) were also applied to characterize COF TZ-BPTA and the modified column. In SEM, it can be seen that COF TZ-BPTA was the spherical shape and the modified capillary was covered with globular particles equably. The COF TZ-BPTA coated column exhibited good separation resolution and efficiency towards two antiepileptic drugs and other kinds of small organic molecules involving alkylbenzene, sulfonamides, polycyclic aromatic hydrocarbon (PAH), parabens, amino acids and herbicides. The maximum column efficiency was over 2.8 × 105 plates·m-1. In addition, the precisions (RSDs) of the retention times for the alkylbenzenes of intra-day runs (n = 3), inter-day runs (n = 3) and column-to-column runs (n = 3) were all less than 1.70% and separation performance was without obvious change within 100 times run. In addition, the real sample was tested on COF TZ-BPTA coated column. Hence, COF TZ-BPTA showed great potential in the separation domain.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, School of Pharmaceutical Sciences, Wuhan University, Wuhan 430072, China; Key Laboratory of Combinatorial Biosynthesis and Drug D…
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Fu, Y., Li, Z., Hu, C., Li, Q., & Chen, Z. (2023). In-situ immobilization of covalent organic frameworks as stationary phase for capillary electrochromatography. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2023.464205
Vancouver
Fu Y, Li Z, Hu C, Li Q, Chen Z. In-situ immobilization of covalent organic frameworks as stationary phase for capillary electrochromatography. Journal of Chromatography A. 2023. doi:10.1016/j.chroma.2023.464205
BibTeX
@article{Fu2023,
author = {Fu, Yuanyuan and Li, Zhentao and Hu, Changjun and Li, Qiaoyan and Chen, Zilin},
title = {In-situ immobilization of covalent organic frameworks as stationary phase for capillary electrochromatography},
journal = {Journal of Chromatography A},
year = {2023},
doi = {10.1016/j.chroma.2023.464205}
}
EUVIMED