Development and validation of a liquid chromatography-triple quadrupole mass spectrometry method for the determination of isopeptide ε-(γ-glutamyl) lysine in human urine as biomarker for transglutaminase 2 cross-linked proteins
Journal of Chromatography A · 2023
DOI: 10.1016/j.chroma.2023.464002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chromatography A, 2023. Verfasst von Lien Dejager und 16 weiteren Autor:innen. Beteiligte Einrichtung: UCB Pharma, Chemin du Foriest, B-1420 Braine-l'Alleud, Belgium. Electronic address: lien.dejager@ucb.com. Hauptthemen laut MEDLINE: Protein Glutamine gamma Glutamyltransferase 2, Lysine. Die Arbeit nennt 27 Literaturangaben. Gefördert von: UCB.
Abstract (Originalsprache)
Determination of the levels of protein cross-linking catalysed by the activity of transglutaminase 2 in various disease states has remained a significant challenge. The ability to quantify the isopeptide ε-(γ-glutamyl) lysine, which can form as a heterogeneous bond within or between proteins has significant analytical and clinical potential as a biomarker in biofluids such as human urine. Increased transglutaminase 2 activity is associated with a number of diseases, such as fibrosis. Previously published methods have been based on classical amino acid analysis, however they require a complex multi-enzyme digestion in order to achieve complete protein digestion, whilst leaving the isopeptide cross link intact. These methods require high levels of enzymes, which contaminate the analysis and alter the dynamics of digestion. The amino acid analysis detection also lacked selectivity, especially where the levels of crosslink are expected to be low relative to the background protein levels. We have systematically addressed these challenges, by optimising the precipitation of the protein in urine, the use of innovative immobilised enzyme technology, which allows for efficient digestion without enzyme contamination and LC-MS/MS detection based on multiple reaction monitoring. This method was validated for its analytical performance characteristics, showing the method has a sensitivity of 0.1 ng/mL of ε-(γ-glutamyl) lysine in human urine with precision of less than 20% CV, and is selective as no interferences were observed that may adversely affect the analysis. As such this approach represents a significant advance in the ability to detect and quantify ε-(γ-glutamyl) lysine.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- UCB Pharma, Chemin du Foriest, B-1420 Braine-l'Alleud, Belgium. Electronic address: lien.dejager@ucb.com.
- UCB Pharma, 208 Bath Road, Slough, SL1 3WE United Kingdom.
- INOFEA AG, Hofackerstrasse 40B, Muttenz CH-4132, Switzerland.
- University of Applied Sciences and Arts Northwestern, Switzerland.
- University of Buffalo, Buffalo, NY 14260, United States.
- DDS (Drug Development Solutions), Newmarket Rd, Fordham, CB7 5WW, United Kingdom.
Förderung
- UCB
Zitieren
APA
Dejager, L., Jairaj, M., Jones, K., Johnson, T., Dudal, S., Dudal, Y., Shahgaldian, P., Correro, R., Qu, J., An, B., Lucey, R., Szarka, S., Wheller, R., Pruna, A., Kettell, S., Pitt, A., & Cutler, P. (2023). Development and validation of a liquid chromatography-triple quadrupole mass spectrometry method for the determination of isopeptide ε-(γ-glutamyl) lysine in human urine as biomarker for transglutaminase 2 cross-linked proteins. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2023.464002
Vancouver
Dejager L, Jairaj M, Jones K, Johnson T, Dudal S, Dudal Y, et al. Development and validation of a liquid chromatography-triple quadrupole mass spectrometry method for the determination of isopeptide ε-(γ-glutamyl) lysine in human urine as biomarker for transglutaminase 2 cross-linked proteins. Journal of Chromatography A. 2023. doi:10.1016/j.chroma.2023.464002
BibTeX
@article{Dejager2023,
author = {Dejager, Lien and Jairaj, Mark and Jones, Kieran and Johnson, Timothy and Dudal, Sherri and Dudal, Yves and Shahgaldian, Patrick and Correro, Rita and Qu, Jun and An, Bo and Lucey, Richard and Szarka, Szabolcs and Wheller, Robert and Pruna, Alina and Kettell, Sarah and Pitt, Andrew and Cutler, Paul},
title = {Development and validation of a liquid chromatography-triple quadrupole mass spectrometry method for the determination of isopeptide ε-(γ-glutamyl) lysine in human urine as biomarker for transglutaminase 2 cross-linked proteins},
journal = {Journal of Chromatography A},
year = {2023},
doi = {10.1016/j.chroma.2023.464002}
}
EUVIMED