The Association Between Mechanical Power Within the First 24 Hours and ICU Mortality in Mechanically Ventilated Adult Patients With Acute Hypoxemic Respiratory Failure
CHEST · 2025-10 · 168 (4) · 901-911
DOI: 10.1016/j.chest.2025.03.012 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift CHEST, 2025-10. Verfasst von Stephan von Düring und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Intensive Care Medicine, Department of Acute Care Medicine, Geneva University Hospitals, Geneva, Switzerland; Department of Anaesthesiolo…. Hauptthemen laut MEDLINE: Hypoxia, Intensive Care Units, Respiration, Artificial, Respiratory Insufficiency. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hôpitaux Universitaires de Genève, University of Toronto.
Abstract (Originalsprache)
BACKGROUND: Despite the widespread adoption of lung-protective ventilation strategies, mortality among patients receiving invasive mechanical ventilation (IMV) remains high. Mechanical power (MP) integrates various variables responsible for ventilator-induced lung injury and has been associated with mortality in patients with ARDS. However, the impact of MP on ICU mortality in the larger group of patients with acute hypoxemic respiratory failure (AHRF) has not been well established, and previous studies have reported inconsistent thresholds for predicting outcomes. RESEARCH QUESTION: Is high MP (> 17 J/min) within the first 24 hours of IMV, calculated using dynamic driving pressure, associated with ICU mortality in patients with AHRF? Additionally, does a threshold exist below which IMV is considered safe? STUDY DESIGN AND METHODS: In this multicenter cohort study, we included adult patients with AHRF who received IMV. Patients were excluded if they received IMV for > 24 hours before inclusion or were receiving extracorporeal life support. We applied multivariable logistic regression models with inverse probability of treatment weighting and used change-point regression models with restricted cubic splines. RESULTS: Of the 21,714 patients in our registry, 9,031 patients (42%) met the inclusion criteria. After adjusting for baseline characteristics, high MP was associated with increased ICU mortality (OR, 1.58; 95% CI, 1.44-1.72), with a nonlinear dose-response relationship. No consistent safe MP threshold was identified. High MP also was associated with lower extubation rates and fewer ventilator-free days. INTERPRETATION: In this study, exposure to high MP within the first 24 hours of IMV was associated with increased ICU mortality in patients with AHRF. The absence of a consistent safe threshold suggests that reducing MP at IMV initiation may be a strategy to improve outcomes, warranting exploration in clinical trials.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Intensive Care Medicine, Department of Acute Care Medicine, Geneva University Hospitals, Geneva, Switzerland; Department of Anaesthesiology, Pharmacology, Intensive Care and Emergency Medicine, Faculty of Me…
- Institute of Health Policy, Management and Evaluation, University of Toronto, Toronto, ON, Canada.
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, ON, Canada; Institute of Health Policy, Management and Evaluation, University of Toronto, Toronto, ON, Canada; Department of Medicine…
- Institute of Health Policy, Management and Evaluation, University of Toronto, Toronto, ON, Canada; Department of Medicine, University of Toronto, Toronto, ON, Canada; Division of Nephrology, University Health Network, T…
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, ON, Canada; Department of Anesthesiology & Pain Medicine, University of Toronto, Toronto, ON, Canada; Toronto General Hospital Resear…
- Interdepartmental Division of Critical Care Medicine, University of Toronto, Toronto, ON, Canada; Institute of Health Policy, Management and Evaluation, University of Toronto, Toronto, ON, Canada; Department of Critical…
Förderung
- Hôpitaux Universitaires de Genève
- University of Toronto
Zitieren
APA
von Düring, S., Liu, K., Munshi, L., Kim, S. J., Urner, M., Adhikari, N. K. J., Parhar, K. K. S., & Fan, E. (2025). The Association Between Mechanical Power Within the First 24 Hours and ICU Mortality in Mechanically Ventilated Adult Patients With Acute Hypoxemic Respiratory Failure. CHEST, 168(4), 901-911. https://doi.org/10.1016/j.chest.2025.03.012
Vancouver
von Düring S, Liu K, Munshi L, Kim SJ, Urner M, Adhikari NKJ, et al. The Association Between Mechanical Power Within the First 24 Hours and ICU Mortality in Mechanically Ventilated Adult Patients With Acute Hypoxemic Respiratory Failure. CHEST. 2025;168(4):901-911. doi:10.1016/j.chest.2025.03.012
BibTeX
@article{vonDring2025,
author = {von Düring, Stephan and Liu, Kuan and Munshi, Laveena and Kim, S Joseph and Urner, Martin and Adhikari, Neill K J and Parhar, Ken Kuljit S and Fan, Eddy},
title = {The Association Between Mechanical Power Within the First 24 Hours and ICU Mortality in Mechanically Ventilated Adult Patients With Acute Hypoxemic Respiratory Failure},
journal = {CHEST},
year = {2025},
volume = {168},
number = {4},
pages = {901--911},
doi = {10.1016/j.chest.2025.03.012}
}
EUVIMED