Physiologic Comparison of Airway Pressure Release Ventilation and Low Tidal Volume Ventilation in ARDS
CHEST · 2025-02 · 167 (2) · 453-465
DOI: 10.1016/j.chest.2024.08.050 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift CHEST, 2025-02. Verfasst von Xiaojing Zou und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Critical Care Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China. Hauptthemen laut MEDLINE: Respiratory Distress Syndrome, Continuous Positive Airway Pressure, Respiration, Artificial. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 49 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The physiologic effects of different ventilation strategies on patients with ARDS need to be better understood. RESEARCH QUESTION: In patients with ARDS receiving controlled mandatory ventilation, does airway pressure release ventilation (APRV) improve lung ventilation/perfusion (V˙/Q˙) matching and ventilation homogeneity compared with low tidal volume (LTV) ventilation? STUDY DESIGN AND METHODS: This study was a single-center randomized controlled trial. Patients with moderate to severe ARDS were ventilated randomly with APRV or LTV ventilation. Electrical impedance tomography (EIT) was used to assess lung ventilation and perfusion. EIT-based data and clinical variables related to respiratory and hemodynamic conditions were collected shortly before randomization (0 hours) and at 12 and 24 hours after randomization. RESULTS: A total of 40 patients were included and randomized to the APRV or LTV ventilation group (20 per group). During the 24-hour trial period, patients receiving APRV exhibited significantly increased dorsal ventilation (difference value [24 hours minus 0 hours]: median, 10.82% [interquartile range (IQR), 2.62%-13.74%] vs 0.12% [IQR, -2.81% to 4.76%]; P = .017), decreased dorsal shunt (median, -4.67% [IQR, -6.83% to 0.59%] vs 1.73% [IQR, -0.95% to 5.53%]; P = .008), and increased dorsal V˙/Q˙ matching (median, 4.13% [IQR, -0.26% to 10.47%] vs -3.29% [IQR, -5.05% to 2.81%]; P = .026) than those receiving LTV ventilation. No difference in ventral dead space was observed between study groups (P = .903). Additionally, two indicators of ventilation distribution heterogeneity, global inhomogeneity index and center of ventilation, significantly decreased and significantly increased, respectively, in the APRV group compared with the LTV ventilation group. Patients receiving APRV showed significantly higher Pao2 to Fio2 ratio, higher respiratory system static compliance and lower Paco2 than those receiving LTV ventilation at 24 hours. The cardiac output was comparable in both groups. INTERPRETATION: APRV, as compared with LTV ventilation, could recruit dorsal region, reduce dorsal shunt, increase dorsal V˙/Q˙ matching, and improve ventilation homogeneity of the lungs, leading to better gas exchange and respiratory system static compliance in patients with moderate to severe ARDS. CLINICAL TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT05767125; URL: www. CLINICALTRIALS: gov.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Critical Care Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
- Department of Epidemiology and Biostatistics, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
- Department of Critical Care Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
- Department of Critical Care Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China. Electronic address: you_shanghust@163.com.
- School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, Guangdong, China; Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany.
Zitieren
APA
Zou, X., Zhang, H., Wu, Y., Li, R., Gao, X., Wang, A., Zhao, X., Yang, X., Shu, H., Qi, H., Fu, Z., Yuan, S., Ma, Y., Yang, L., Shang, Y., & Zhao, Z. (2025). Physiologic Comparison of Airway Pressure Release Ventilation and Low Tidal Volume Ventilation in ARDS. CHEST, 167(2), 453-465. https://doi.org/10.1016/j.chest.2024.08.050
Vancouver
Zou X, Zhang H, Wu Y, Li R, Gao X, Wang A, et al. Physiologic Comparison of Airway Pressure Release Ventilation and Low Tidal Volume Ventilation in ARDS. CHEST. 2025;167(2):453-465. doi:10.1016/j.chest.2024.08.050
BibTeX
@article{Zou2025,
author = {Zou, Xiaojing and Zhang, Hongling and Wu, Yongran and Li, Ruiting and Gao, Xuehui and Wang, Azhen and Zhao, Xin and Yang, Xiaobo and Shu, Huaqing and Qi, Hong and Fu, Zhaohui and Yuan, Shiying and Ma, Yilei and Yang, Le and Shang, You and Zhao, Zhanqi},
title = {Physiologic Comparison of Airway Pressure Release Ventilation and Low Tidal Volume Ventilation in ARDS},
journal = {CHEST},
year = {2025},
volume = {167},
number = {2},
pages = {453--465},
doi = {10.1016/j.chest.2024.08.050}
}
EUVIMED