EUVIMEDEUVIMED entdecken
Crossref

Directly measuring octanol-air partition ratios using a gas chromatography retention time (GC-RT) method

Anya Guo, Holly McKenzie, Jeffery Okoroma, Parshawn Amini, Megan Fair, Kirk M Green, Amandeep Saini, Liisa Jantunen, Joseph O Okeme

Chemosphere · 2024

DOI: 10.1016/j.chemosphere.2024.143544 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Chemosphere, 2024. Verfasst von Anya Guo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario, L8S 4M1, Canada. Electronic address: guoa25@mcmaster.ca. Hauptthemen laut MEDLINE: Volatile Organic Compounds, Octanols, Gas Chromatography-Mass Spectrometry. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The octanol-air partition ratio (KOA) is a fundamental property used for screening chemicals for concern, depending on their potential to bioaccumulate and harm living systems. With millions of chemicals used in commerce, unfortunately, less than 800 compounds currently have experimentally measured KOA values due to limitations in traditional measurement techniques. We aimed to develop a direct gas chromatography retention time (GC-RT) method using a custom-packed column, with octanol as the stationary phase, for rapidly measuring KOA. We installed the column into a GC-mass spectrometry system and isothermally measured retention times of 15 volatile organic compounds. We calculated KOA values at experimental temperatures from the retention times and extrapolated the results to values at 25 °C using the Van't Hoff equation. Our directly measured log KOA values at 25 °C spanned 3.66 log units (0.820-4.48). Except for alcohols, our measured values agree with literature log KOA values (root mean square error, RMSE = 0.50). The discrepancy probably arose from differences in how well our method versus the literature methods capture measurement artifacts, specifically, gas-phase adsorption to the octanol phase and hydrogen bonding interactions. This proof-of-concept study demonstrates that our direct GC-RT method is promising for rapidly measuring KOA to support chemical risk assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Volatile Organic CompoundsOctanolsGas Chromatography-Mass SpectrometryAirChromatography, GasTemperature

Stichwörter der Autor:innen

BioaccumulationChromatographyDirect methodK(OA)Octanol-air partition ratioPacked column

Substanzen

Volatile Organic CompoundsOctanols

Autor:innen und Institutionen

  • Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario, L8S 4M1, Canada. Electronic address: guoa25@mcmaster.ca.
  • Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario, L8S 4M1, Canada; School of Chemistry, University of Bristol, Bristol, BS8 1QU, United Kingdom. Electronic address: zn20368@bristol.ac…
  • Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario, L8S 4M1, Canada. Electronic address: okoromaj@mcmaster.ca.
  • Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario, L8S 4M1, Canada. Electronic address: aminip@mcmaster.ca.
  • Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario, L8S 4M1, Canada. Electronic address: fairmg@mcmaster.ca.
  • Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario, L8S 4M1, Canada. Electronic address: greenmk@mcmaster.ca.

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Guo, A., McKenzie, H., Okoroma, J., Amini, P., Fair, M., Green, K. M., Saini, A., Jantunen, L., & Okeme, J. O. (2024). Directly measuring octanol-air partition ratios using a gas chromatography retention time (GC-RT) method. Chemosphere. https://doi.org/10.1016/j.chemosphere.2024.143544

Vancouver

Guo A, McKenzie H, Okoroma J, Amini P, Fair M, Green KM, et al. Directly measuring octanol-air partition ratios using a gas chromatography retention time (GC-RT) method. Chemosphere. 2024. doi:10.1016/j.chemosphere.2024.143544

BibTeX
@article{Guo2024,
  author = {Guo, Anya and McKenzie, Holly and Okoroma, Jeffery and Amini, Parshawn and Fair, Megan and Green, Kirk M and Saini, Amandeep and Jantunen, Liisa and Okeme, Joseph O},
  title = {Directly measuring octanol-air partition ratios using a gas chromatography retention time (GC-RT) method},
  journal = {Chemosphere},
  year = {2024},
  doi = {10.1016/j.chemosphere.2024.143544}
}
Kostenlos starten →