Integrating of electrocoagulation process with submerged membrane bioreactor for wastewater treatment under low voltage gradients
Chemosphere · 2023-10 · 339 · 139693
DOI: 10.1016/j.chemosphere.2023.139693 ↗Kurz gefasst
Fachartikel in der Zeitschrift Chemosphere, 2023-10. Verfasst von Khalid Bani-Melhem und 6 weiteren Autor:innen. Beteiligte Einrichtung: Water Technology Unit (WTU), Center for Advanced Materials (CAM). Qatar University, P.O. Box 2713, Doha, Qatar. Electronic address: kmelhem@qu.edu.qa. Hauptthemen laut MEDLINE: Water Purification, Environmental Pollutants. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 72 Literaturangaben. Gefördert von: King Abdullah University of Science and Technology, American University in Cairo, Concordia University.
Abstract (Originalsprache)
Treating and reusing wastewater has become an essential aspect of water management worldwide. However, the increase in emerging pollutants such as polycyclic aromatic hydrocarbons (PAHs), which are presented in wastewater from various sources like industry, roads, and household waste, makes their removal difficult due to their low concentration, stability, and ability to combine with other organic substances. Therefore, treating a low load of wastewater is an attractive option. The study aimed to address membrane fouling in the submerged membrane bioreactor (SMBR) used for wastewater treatment. An aluminum electrocoagulation (EC) device was combined with SMBR as a pre-treatment to reduce fouling. The EC-SMBR process was compared with a conventional SMBR without EC, fed with real grey water. To prevent impeding biological growth, low voltage gradients were utilized in the EC deviceThe comparison was conducted over 60 days with constant transmembrane pressure and infinite solid retention time (SRT). In phase I, when the EC device was operated at a low voltage gradient (0.64 V/cm), no significant improvement in the pollutants removal was observed in terms of color, turbidity, and chemical oxygen demand (COD). Nevertheless, during phase II, a voltage gradient of 1.26 V/cm achieved up to 100%, 99.7%, 92%, 94.1%, and 96.5% removals in the EC-SMBR process in comparison with 95.1%, 95.4%, 85%, 91.7% and 74.2% removals in the SMBR process for turbidity, color, COD, ammonia nitrogen (NH3-N), total phosphorus (TP), respectively. SMBR showed better anionic surfactant (AS) removal than EC-SMBR. A voltage gradient of 0.64 V/cm in the EC unit significantly reduced fouling by 23.7%, while 1.26 V/cm showed inconsistent results. Accumulation of Al ions negatively affected membrane performance. Low voltage gradients in EC can control SMBR fouling if Al concentration is controlled. Future research should investigate EC-SMBR with constant membrane flux for large-scale applications, considering energy consumption and operating costs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Water Technology Unit (WTU), Center for Advanced Materials (CAM). Qatar University, P.O. Box 2713, Doha, Qatar. Electronic address: kmelhem@qu.edu.qa.
- Dept. of Building, Civil and Environmental Engineering, Concordia University, 1455 Blvd de Maisonneuve W., Montreal, Quebec, H3G 1M8, Canada.
- Sustainable and Renewable Energy Engineering Department, University of Sharjah, Sharjah, P.O. Box 27272, United Arab Emirates; Sustainable Energy & Power Systems Research Centre, RISE, University of Sharjah, P.O. Box 27…
- Al-Balqa Applied University, Al-Huson University College, Department of Chemical Engineering, Jordan.
- Environmental Engineering Program, Department of Construction and Architectural Engineering, School of Sciences and Engineering, The American University in Cairo, New Cairo, Egypt.
- Faculty of Architecture and Urbanism, UTE University, Calle Rumipamba S/N and Bourgeois, Quito, Ecuador; Department of Biomaterials, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Scie…
Förderung
- King Abdullah University of Science and Technology
- American University in Cairo
- Concordia University
Zitieren
APA
Bani-Melhem, K., Elektorowicz, M., Tawalbeh, M., Al Bsoul, A., El Gendy, A., Kamyab, H., & Yusuf, M. (2023). Integrating of electrocoagulation process with submerged membrane bioreactor for wastewater treatment under low voltage gradients. Chemosphere, 339, 139693. https://doi.org/10.1016/j.chemosphere.2023.139693
Vancouver
Bani-Melhem K, Elektorowicz M, Tawalbeh M, Al Bsoul A, El Gendy A, Kamyab H, et al. Integrating of electrocoagulation process with submerged membrane bioreactor for wastewater treatment under low voltage gradients. Chemosphere. 2023;339:139693. doi:10.1016/j.chemosphere.2023.139693
BibTeX
@article{BaniMelhem2023,
author = {Bani-Melhem, Khalid and Elektorowicz, Maria and Tawalbeh, Muhammad and Al Bsoul, Abeer and El Gendy, Ahmed and Kamyab, Hesam and Yusuf, Mohammad},
title = {Integrating of electrocoagulation process with submerged membrane bioreactor for wastewater treatment under low voltage gradients},
journal = {Chemosphere},
year = {2023},
volume = {339},
pages = {139693},
doi = {10.1016/j.chemosphere.2023.139693}
}
EUVIMED