EUVIMEDEUVIMED entdecken
Multizentrische Studie

INTELCAPE: A Deep Learning-Powered System for Automated, High-Accuracy Crohn’s Disease Diagnosis via Capsule Endoscopy

Dejun Fan, Yize Mao, Feng Liang, Zheng Liu, Huayu Li, Jian Tang, Yanan Liu, Mingjie Wang, Yuting Qian, Jie Chen, Neng Wang, Tao Yang und 5 weitere

Clinical Gastroenterology and Hepatology · 2026-09 · 24 (9) · 2571-2583

DOI: 10.1016/j.cgh.2026.02.026 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Clinical Gastroenterology and Hepatology, 2026-09. Verfasst von Dejun Fan und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastrointestinal Endoscopy, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China; Guangdong Provincial Key Laborator…. Hauptthemen laut MEDLINE: Capsule Endoscopy, Crohn Disease, Deep Learning. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND & AIMS: Capsule endoscopy (CE) is a noninvasive technique for diagnosing Crohn's disease (CD); however, manual interpretation of CE videos is time-consuming and error-prone. We developed an artificial intelligence system, INTELCAPE, to automate CE video analysis for accurate and efficient CD diagnosis. METHODS: This retrospective, multi-center study used data from 2 Chinese hospitals. A multi-task deep learning framework segmented small-intestine regions, detected lesions, and diagnosed CD using CE videos from 757 (Cohort 1) and 115 (Cohort 2) patients. INTELCAPE integrated the ResNet, Transformer, and EfficientNet architectures for hierarchical processing. Performance was benchmarked against clinicians using 3 metrics. This study received Ethics Committee approval (2024ZSLYEC-040). RESULTS: INTELCAPE achieved state-of-the-art performance across all tasks. For small-intestine segmentation, the model showed intersection over union scores of 94.82% (Cohort 1, 95% confidence interval, 93.28%-96.36%) and 96.87% (Cohort 2, 95% confidence interval, 94.63%-99.12%). For lesion detection, it achieved area under the curve values of 0.993 (Cohort 1) and 0.980 (Cohort 2), with 99.33% classification accuracy, which was comparable to that of specialists (97.83%) but superior to that of residents (91.05%; P < .001). For CD diagnosis, INTELCAPE demonstrated robust generalizability, achieving area under the curve values of 0.982 (Cohort 1) and 0.984 (Cohort 2) with 90% diagnostic accuracy, comparable to that of specialists (93.33%) but 10-fold faster (P < .001). INTELCAPE improved doctors' diagnostic accuracy (76.7%-94.8%; P < .001), while reducing their interpretation time (67.9-22.5 minutes; P < .001). CONCLUSIONS: INTELCAPE improved CD diagnosis by automating CE video analysis, thereby enhancing accuracy and efficiency, particularly for less-experienced clinicians.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Capsule EndoscopyCrohn DiseaseDeep LearningHumansRetrospective StudiesFemaleChinaMaleAdult

Stichwörter der Autor:innen

AI-Assisted DiagnosisArtificial IntelligenceCapsule EndoscopyCrohn’s Disease

Autor:innen und Institutionen

  • Department of Gastrointestinal Endoscopy, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China; Guangdong Provincial Key Laboratory of Colorectal and Pelvic Floor Diseases, The Sixth Affiliated Hospit…
  • State Key Laboratory of Oncology in South China, Department of Pancreatobiliary Surgery, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China.
  • Artificial Intelligence Research Institute, Shenzhen MSU-BIT University, Shenzhen, China.
  • School of Computer Science and Engineering, Sun Yat-sen University, Guangzhou, China.
  • State Key Laboratory of Oncology in South China, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, China.
  • Department of Gastroenterology, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.

Zitieren

APA

Fan, D., Mao, Y., Liang, F., Liu, Z., Li, H., Tang, J., Liu, Y., Wang, M., Qian, Y., Chen, J., Wang, N., Yang, T., Tan, S., Li, G., Gao, F., Hu, J., & Wu, X. (2026). INTELCAPE: A Deep Learning-Powered System for Automated, High-Accuracy Crohn’s Disease Diagnosis via Capsule Endoscopy. Clinical Gastroenterology and Hepatology, 24(9), 2571-2583. https://doi.org/10.1016/j.cgh.2026.02.026

Vancouver

Fan D, Mao Y, Liang F, Liu Z, Li H, Tang J, et al. INTELCAPE: A Deep Learning-Powered System for Automated, High-Accuracy Crohn’s Disease Diagnosis via Capsule Endoscopy. Clinical Gastroenterology and Hepatology. 2026;24(9):2571-2583. doi:10.1016/j.cgh.2026.02.026

BibTeX
@article{Fan2026,
  author = {Fan, Dejun and Mao, Yize and Liang, Feng and Liu, Zheng and Li, Huayu and Tang, Jian and Liu, Yanan and Wang, Mingjie and Qian, Yuting and Chen, Jie and Wang, Neng and Yang, Tao and Tan, Shuangyi and Li, Guanbin and Gao, Feng and Hu, Jiancong and Wu, Xiaojian},
  title = {INTELCAPE: A Deep Learning-Powered System for Automated, High-Accuracy Crohn’s Disease Diagnosis via Capsule Endoscopy},
  journal = {Clinical Gastroenterology and Hepatology},
  year = {2026},
  volume = {24},
  number = {9},
  pages = {2571--2583},
  doi = {10.1016/j.cgh.2026.02.026}
}
Kostenlos starten →