EUVIMEDEUVIMED entdecken
Crossref

Establishment of a multi-parameter flow cytometry method to identify and characterize neutrophil extracellular traps

Weixiang Liu, Jieming Ping, Ning Wu

Cellular Immunology · 2025

DOI: 10.1016/j.cellimm.2025.105014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cellular Immunology, 2025. Verfasst von Weixiang Liu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Immunology, School of Basic Medicine, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430000, China. Hauptthemen laut MEDLINE: Extracellular Traps, Flow Cytometry, Neutrophils. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 60 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Neutrophil extracellular traps (NETs) are web-like decondensed DNA filaments released by activated neutrophils, decorated with antimicrobial proteins such as myeloperoxidase (MPO) and elastase. Although several methods exist to evaluate NETs formation, including fluorescent microscopy or scanning electron microscopy (SEM), and flow cytometry, each has inherent limitations that restrict widespread application. Given the increasing relevance of NETs in various pathophysiological contexts, we sought to develop a simple, specific, objective and cost-effective flow cytometry-based method to assess NETs both in vitro and in vivo. Our approach leverages multi-parametric flow cytometry to simultaneously evaluate cell size, granularity, DNA decondensation, histone citrullination, and intracellular MPO. This method enables reliable detection of NETs in purified neutrophils as well as in tissue samples. Its performance was validated in parallel with conventional microscopy, confirming specificity and reproducibility. Notably, this FACS-based method is faster, more economical, and free from observer-bias, making it especially well-suited for both research and clinical sample analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Extracellular TrapsFlow CytometryNeutrophilsHumansPeroxidaseReproducibility of ResultsAnimalsMiceHistonesNeutrophil Activation

Stichwörter der Autor:innen

Acute lung injury (ALI)Cit-H3HoechstMPOMulti-parameter FACSNeutrophil extracellular traps (NETs)

Substanzen

PeroxidaseHistones

Autor:innen und Institutionen

  • Department of Immunology, School of Basic Medicine, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430000, China.
  • Department of Immunology, School of Basic Medicine, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430000, China; The First Affiliated Hospital of Anhui Medical University and Institute of…

Zitieren

APA

Liu, W., Ping, J., & Wu, N. (2025). Establishment of a multi-parameter flow cytometry method to identify and characterize neutrophil extracellular traps. Cellular Immunology. https://doi.org/10.1016/j.cellimm.2025.105014

Vancouver

Liu W, Ping J, Wu N. Establishment of a multi-parameter flow cytometry method to identify and characterize neutrophil extracellular traps. Cellular Immunology. 2025. doi:10.1016/j.cellimm.2025.105014

BibTeX
@article{Liu2025,
  author = {Liu, Weixiang and Ping, Jieming and Wu, Ning},
  title = {Establishment of a multi-parameter flow cytometry method to identify and characterize neutrophil extracellular traps},
  journal = {Cellular Immunology},
  year = {2025},
  doi = {10.1016/j.cellimm.2025.105014}
}
Kostenlos starten →