EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access · CC BY-NC-ND 4.0

Main air pollutants and ventricular arrhythmias in patients with implantable cardioverter‐defibrillators: A systematic review and meta‐analysis

Hong-Jie Yang, Xin Liu, Chuan Qu, Shao-Bo Shi, Jin-Jun Liang, Bo Yang

Chronic Diseases and Translational Medicine · 2017-12 · 3 (4) · 242-251

DOI: 10.1016/j.cdtm.2017.09.001 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Chronic Diseases and Translational Medicine, 2017-12. Verfasst von Hong-Jie Yang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, Hubei 430060, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Key Program of Natural Science Foundation of Hubei Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Previous studies of ambient air pollutants and ventricular arrhythmias in patients with implantable cardioverter‐defibrillator (ICD) have yielded mixed results, and the association between air pollution and ventricular arrhythmias in these patients remains unclear. This study aimed to assess and quantify the association between exposure to major air pollutants [CO, inhalable particles (PM 10 ), SO 2 , fine particulate matter (PM 2.5 ), O 3 , and NO 2 ] and the presence of ventricular arrhythmia in patients with ICD.

Methods

The Medline, PubMed, Web of Science, Global Health Library, Virtual Health Library, Population Information Online (POPLINE), and New York Academy of Medicine Grey Literature Report databases were searched to identify studies analyzing the association between ventricular arrhythmias in patients with ICD and the abovementioned main air pollutants. Pooled estimates were generated using a random‐effects model or fixed‐effects model, according to the value of heterogeneity. Heterogeneity within studies was assessed using Cochran's Q and I 2 statistics. Funnel plots, Egger's regression test, and Begg's rank correlation method were used to evaluate publication bias. Sensitivity analyses were also conducted to evaluate the potential sources of heterogeneity.

Results

After a detailed screening of 167 studies, seven separate studies were identified. Ventricular arrhythmias in patients with ICD were found to be positively, but not significantly, associated with CO, PM 10 , SO 2 , PM 2.5 , and NO 2, with a pooled estimate [odds ratio ( OR ) associated with each 10 μg/m 3 increase in pollutant concentration, except for CO, which was associated with each 1 mg/m 3 increase in concentration] of 1.03 [95% confidence interval ( CI ): 0.92–1.17, P = 0.59] for CO, 1.01 (95% CI : 0.97–1.05, P = 0.55) for PM 10 , 1.09 (95% CI : 0.95–1.24, P = 0.22) for SO 2, 1.07 (95% CI : 0.95–1.21, P = 0.25) for PM 2.5 , and 1.06 (95% CI : 0.98–1.14, P = 0.16) for NO 2 . No increased risk of ventricular arrhythmias in patients with ICD was found to be associated with O 3 ( OR = 1.00; 95% CI : 0.98–1.01, P = 0.56).

Conclusions

The results of this study provide little evidence that ambient air pollutants affect the risk of ICD discharges for treating ventricular arrhythmias.

Schlagwörter

Stichwörter der Autor:innen

Air pollutantsImplantable cardioverter-defibrillatorSystematic reviewVentricular arrhythmia

Autor:innen und Institutionen

  • Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, Hubei 430060, China.
  • Cardiovascular Research Institute, Wuhan University, Wuhan, Hubei 430060, China.
  • Hubei Key Laboratory of Cardiology, Wuhan, Hubei 430060, China.

Förderung

  • Key Program of Natural Science Foundation of Hubei Province

Zitieren

APA

Yang, H. J., Liu, X., Qu, C., Shi, S. B., Liang, J. J., & Yang, B. (2017). Main air pollutants and ventricular arrhythmias in patients with implantable cardioverter‐defibrillators: A systematic review and meta‐analysis. Chronic Diseases and Translational Medicine, 3(4), 242-251. https://doi.org/10.1016/j.cdtm.2017.09.001

Vancouver

Yang HJ, Liu X, Qu C, Shi SB, Liang JJ, Yang B. Main air pollutants and ventricular arrhythmias in patients with implantable cardioverter‐defibrillators: A systematic review and meta‐analysis. Chronic Diseases and Translational Medicine. 2017;3(4):242-251. doi:10.1016/j.cdtm.2017.09.001

BibTeX
@article{Yang2017,
  author = {Yang, Hong-Jie and Liu, Xin and Qu, Chuan and Shi, Shao-Bo and Liang, Jin-Jun and Yang, Bo},
  title = {Main air pollutants and ventricular arrhythmias in patients with implantable cardioverter‐defibrillators: A systematic review and meta‐analysis},
  journal = {Chronic Diseases and Translational Medicine},
  year = {2017},
  volume = {3},
  number = {4},
  pages = {242--251},
  doi = {10.1016/j.cdtm.2017.09.001}
}
Kostenlos starten →