EUVIMEDEUVIMED entdecken
FallberichtÜbersichtsarbeit

Bachmann Bundle Pacing Combined with ICD in Hypertrophic Cardiomyopathy with Interatrial Conduction Block

Shengjie Wu, Kelly Q Jia, Xiangxiang Shi, XingXing Chen, Lan Su

Cardiac Electrophysiology Clinics · 2026-09 · 18 (3) · 269-272

DOI: 10.1016/j.ccep.2026.06.004 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Cardiac Electrophysiology Clinics, 2026-09. Verfasst von Shengjie Wu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, the First Affiliated Hospital of Wenzhou Medical University, Nanbaixiang, Wenzhou, 325000, People's Republic of China. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Cardiomyopathy, Hypertrophic, Cardiac Pacing, Artificial, Interatrial Block. Die Arbeit nennt 3 Literaturangaben. Gefördert von: Medical Science and Technology Project of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This case presents a 67-year-old man with familial hypertrophic cardiomyopathy, severe heart failure (LVEF 31%, NYHA III), and significant interatrial conduction delay. After ruling out cardiac resynchronization therapy due to unsuitable ventricular activation characteristics, a dual-chamber implantable cardioverter-defibrillator was implanted, using Bachmann bundle pacing for the atrial lead to optimize interatrial synchrony. BBP successfully corrected the IACD, evidenced by P-wave shortening and normalization. This led to remarkable clinical improvements within 1 month: LVEF increased from 31% to 49%, and NYHA class improved from III to II. Echocardiography confirmed enhanced left atrial-left ventricular coupling. This case demonstrates BBP combined with ICD as a novel and effective strategy for HCM patients with IACD, offering both sudden cardiac death protection and substantial hemodynamic and functional benefits by optimizing atrial activation and atrioventricular synchrony.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantableCardiomyopathy, HypertrophicCardiac Pacing, ArtificialInteratrial BlockHumansMaleAgedElectrocardiography

Stichwörter der Autor:innen

Bachmann bundleHypertrophic cardiomyopathyImplantable cardioverter-defibrillatorInteratrial conduction delay

Autor:innen und Institutionen

  • Department of Cardiology, the First Affiliated Hospital of Wenzhou Medical University, Nanbaixiang, Wenzhou, 325000, People's Republic of China.
  • Department of Cardiac Electrophysiology, Northwell Health - Lenox Hill Hospital, New York, NY, USA.
  • Department of Cardiology, the First Affiliated Hospital of Wenzhou Medical University, Nanbaixiang, Wenzhou, 325000, People's Republic of China. Electronic address: sulan@wzhospital.cn.

Förderung

  • Medical Science and Technology Project of Zhejiang Province

Zitieren

APA

Wu, S., Jia, K. Q., Shi, X., Chen, X., & Su, L. (2026). Bachmann Bundle Pacing Combined with ICD in Hypertrophic Cardiomyopathy with Interatrial Conduction Block. Cardiac Electrophysiology Clinics, 18(3), 269-272. https://doi.org/10.1016/j.ccep.2026.06.004

Vancouver

Wu S, Jia KQ, Shi X, Chen X, Su L. Bachmann Bundle Pacing Combined with ICD in Hypertrophic Cardiomyopathy with Interatrial Conduction Block. Cardiac Electrophysiology Clinics. 2026;18(3):269-272. doi:10.1016/j.ccep.2026.06.004

BibTeX
@article{Wu2026,
  author = {Wu, Shengjie and Jia, Kelly Q and Shi, Xiangxiang and Chen, XingXing and Su, Lan},
  title = {Bachmann Bundle Pacing Combined with ICD in Hypertrophic Cardiomyopathy with Interatrial Conduction Block},
  journal = {Cardiac Electrophysiology Clinics},
  year = {2026},
  volume = {18},
  number = {3},
  pages = {269--272},
  doi = {10.1016/j.ccep.2026.06.004}
}
Kostenlos starten →