EUVIMEDEUVIMED entdecken
Crossref

A rapid sequential salting-out/isoelectric precipitation LC-MS/MS method for quantifying cytokeratin 18 in human ascitic fluid

Zhenni Liu, Xiaohua Xiao, Bingchu Li, Nijiao Qin, Ziyang Li, Xing Lyu, Zhongyuan Xiang, Min Hu, Qichen Long

Clinica Chimica Acta · 2027-03 · 594 · 122869

DOI: 10.1016/j.cca.2026.122869 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinica Chimica Acta, 2027-03. Verfasst von Zhenni Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, the Second Xiangya Hospital, Central South University, Changsha, Hunan, China; Center for Clinical Molecular Diagn…. Die Arbeit nennt 30 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cytokeratin 18 (CK18), a predominant hepatocyte intermediate filament protein released during hepatocyte death, has been investigated as a hepatic injury biomarker. Conventional immunoassays for CK18 suffer from non-specific cross-reactivity and insufficient standardization. Though liquid chromatography-tandem mass spectrometry (LC-MS/MS) could overcome such immunoanalytical drawbacks, accurate CK18 quantification in ascitic fluid remains analytically challenging because of the complex matrix, low target abundance, and variability introduced by protein enrichment and digestion. Herein, we developed a rapid and practical LC-MS/MS method for CK18 quantification in ascitic fluid. A two-step non-immunoaffinity enrichment strategy, integrating sequential ammonium sulfate salting-out and isoelectric point-driven acidic precipitation, was optimized to balance enrichment yield, pretreatment turnaround, and operational cost. Subsequent pretreatment workflow comprising urea denaturation, enzymatic hydrolysis, and solid phase extraction purification can be completed within 6 h, providing an economical, instrument-compatible procedure for LC-MS/MS analysis. Systematic analytical performance evaluation showed satisfactory linearity spanning 0.10-10.36 nmol/L, a limit of quantification of 0.10 nmol/L, a limit of detection of 0.02 nmol/L, total imprecision

Schlagwörter

Stichwörter der Autor:innen

CirrhosisCytokeratin 18Liquid chromatography-mass spectrometryProtein precipitationQuantificationSalting-out

Autor:innen und Institutionen

  • Department of Laboratory Medicine, the Second Xiangya Hospital, Central South University, Changsha, Hunan, China; Center for Clinical Molecular Diagnostics, the Second Xiangya Hospital, Central South University, Changsh…

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Liu, Z., Xiao, X., Li, B., Qin, N., Li, Z., Lyu, X., Xiang, Z., Hu, M., & Long, Q. (2027). A rapid sequential salting-out/isoelectric precipitation LC-MS/MS method for quantifying cytokeratin 18 in human ascitic fluid. Clinica Chimica Acta, 594, 122869. https://doi.org/10.1016/j.cca.2026.122869

Vancouver

Liu Z, Xiao X, Li B, Qin N, Li Z, Lyu X, et al. A rapid sequential salting-out/isoelectric precipitation LC-MS/MS method for quantifying cytokeratin 18 in human ascitic fluid. Clinica Chimica Acta. 2027;594:122869. doi:10.1016/j.cca.2026.122869

BibTeX
@article{Liu2027,
  author = {Liu, Zhenni and Xiao, Xiaohua and Li, Bingchu and Qin, Nijiao and Li, Ziyang and Lyu, Xing and Xiang, Zhongyuan and Hu, Min and Long, Qichen},
  title = {A rapid sequential salting-out/isoelectric precipitation LC-MS/MS method for quantifying cytokeratin 18 in human ascitic fluid},
  journal = {Clinica Chimica Acta},
  year = {2027},
  volume = {594},
  pages = {122869},
  doi = {10.1016/j.cca.2026.122869}
}
Kostenlos starten →