EUVIMEDEUVIMED entdecken
Crossref

Establishment of a R-Sphere labelled immunoassay platform and its rapid combined quantitative detection of ketamine and morphine in serum

Binbin Zhao, Aolin Zhu, Qian Zhang, Ziyue Li, Yongwei Zhang, Meng Liu, Hao Zhou, Tingwei Liu, Xuelei Zhou, Jiutong Li, Jun Zhao, Xinxia Li

Clinica Chimica Acta · 2025

DOI: 10.1016/j.cca.2025.120225 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinica Chimica Acta, 2025. Verfasst von Binbin Zhao und 11 weiteren Autor:innen. Beteiligte Einrichtung: College of Pharmacy, Xinjiang Medical University, Urumqi 830054, China. Hauptthemen laut MEDLINE: Ketamine, Morphine, Microspheres. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND AIMS: Ketamine and morphine are among the most commonly abused drugs. Ketamine is classified as a new psychoactive substance, while morphine represents the opioid class. These two substances may exhibit synergistic or antagonistic effects in their pharmacological actions, and their combined abuse could lead to more severe health risks, such as respiratory depression. Therefore, simultaneous detection is crucial for comprehensive monitoring of drug abuse. This study developed a test strip capable of detecting both ketamine (KET) and morphine (MOP) in serum, utilizing Raman spectroscopy technology to meet the needs of various application scenarios. METHODS: A mixture of Raman microsphere-labelled KET and MOP antibodies was mixed with a mixed standard solution of KET and MOP and added dropwise to the sample pad of the prepared KET and MOP co-assay test strip, chromatographed for 10 min, and then the Raman spectra and Raman signals at the T-line were detected using a Raman spectrometer. RESULTS: The KET and MOP showed good correlation with the Raman signal response values in the concentration ranges of 0.0-100.0 ng/mL and 0.0-4.0 ng/mL, and the limits of detection (LODs) were 1.1986 ng/mL and 0.0113 ng/mL with the coefficients of variation (CV) of less than 10 %, the recoveries were in the ranges of 90 %-110 %, and interfering substances had no effect on the detection results. CONCLUSION: In this study, we developed a method for the quantitative detection of KET and MOP based on the spectroscopic properties of Raman microsphere (R-Sphere) and the principle of competitive immunity, which has the advantages of simple operation, rapidity, high sensitivity, and the possibility of combined detection, which makes the detection efficiency greatly improved.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KetamineMorphineMicrospheresHumansImmunoassaySpectrum Analysis, RamanLimit of Detection

Stichwörter der Autor:innen

KetamineMorphineSimultaneous detection of multiple indicatorsSurface Enhanced Raman Spectroscopy

Substanzen

KetamineMorphine

Autor:innen und Institutionen

  • College of Pharmacy, Xinjiang Medical University, Urumqi 830054, China.
  • Affiliated Tumor Hospital of Xinjiang Medical University, Xinjiang Uygur Autonomous Region, Urumqi 830011, China.
  • Xinjiang Xingyi Bio-Science Co., Ltd., Urumqi 830011, China.
  • College of Pharmacy, Xinjiang Medical University, Urumqi 830054, China; Xinjiang Xingyi Bio-Science Co., Ltd., Urumqi 830011, China.
  • Department of Pharmacy, The First Affiliated Hospital of Xinjiang Medical University, Xinjiang Key Laboratory of Clinical Drug Research, Urumqi 830011, China. Electronic address: zhaojun700326@163.com.
  • College of Pharmacy, Xinjiang Medical University, Urumqi 830054, China; Key Laboratory of High Incidence Disease Research in Xingjiang (Xinjiang Medical University), Ministry of Education, Urumqi 830054, China; Xinjiang…

Zitieren

APA

Zhao, B., Zhu, A., Zhang, Q., Li, Z., Zhang, Y., Liu, M., Zhou, H., Liu, T., Zhou, X., Li, J., Zhao, J., & Li, X. (2025). Establishment of a R-Sphere labelled immunoassay platform and its rapid combined quantitative detection of ketamine and morphine in serum. Clinica Chimica Acta. https://doi.org/10.1016/j.cca.2025.120225

Vancouver

Zhao B, Zhu A, Zhang Q, Li Z, Zhang Y, Liu M, et al. Establishment of a R-Sphere labelled immunoassay platform and its rapid combined quantitative detection of ketamine and morphine in serum. Clinica Chimica Acta. 2025. doi:10.1016/j.cca.2025.120225

BibTeX
@article{Zhao2025,
  author = {Zhao, Binbin and Zhu, Aolin and Zhang, Qian and Li, Ziyue and Zhang, Yongwei and Liu, Meng and Zhou, Hao and Liu, Tingwei and Zhou, Xuelei and Li, Jiutong and Zhao, Jun and Li, Xinxia},
  title = {Establishment of a R-Sphere labelled immunoassay platform and its rapid combined quantitative detection of ketamine and morphine in serum},
  journal = {Clinica Chimica Acta},
  year = {2025},
  doi = {10.1016/j.cca.2025.120225}
}
Kostenlos starten →