Clinical performance and application of novel serum collection “Ser-Col” device in the practice of laboratory diagnosis of infection diseases and several other immunochemical tests
Clinica Chimica Acta · 2025
DOI: 10.1016/j.cca.2024.119970 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinica Chimica Acta, 2025. Verfasst von Hayk Harutyunyan und 11 weiteren Autor:innen. Beteiligte Einrichtung: Neuroscience Laboratory, Cobrain Center, Yerevan State Medical University named after Mkhitar Heratsi, Yerevan, Armenia. Hauptthemen laut MEDLINE: SARS-CoV-2. Die Arbeit nennt 35 Literaturangaben. Gefördert von: Science Committee of the Ministry of Education Science Culture and Sports of the Republic of Armenia, Horizon 2020 European Innovation Council Fast Track to Innovation.
Abstract (Originalsprache)
BACKGROUND: Dried blood collection devices might be beneficial for diagnosing infectious diseases in areas far from the medical facilities and in lockdown situations. There are several reports on the efficacy of such applications for qualitative tests. Here we demonstrated the feasibility of a novel Ser-Col blood collection device as a standardized approach for qualitative and quantitative detection of infectious markers and several over immunochemical tests. METHODS: In the current study, we included 395 adult participants, 191 men and 204 women, with a median age of 41 years, as well as 75 children with a median age of 3 years. Serological status was determined by testing serum samples for three groups of infection diseases: hepatitis A and C, SARS-CoV-2, and herpes family viruses, as well as for thyroid peroxidase (TPO), prolactin, vitamin B12, and folate. Blood collected on the Ser-Col device (Labonovum) was eluted using an automated system (SCAUT Ser-Col automation, Blok System Supply) and manually. Ser-Col results were compared with serum sampled via standard venipuncture considered as the reference. RESULTS: High correlation coefficients (r = 0.95-0.99) were observed between serum samples collected with Ser-Col and via standard venipuncture for the following tests: anti-HCV, anti-SARS-CoV-2 IgG, anti-HSV-2 IgG, and anti-CMV IgM. Correlation coefficients between Ser-Col and standard venipuncture serum for anti-HSV-1 IgG, anti-CMV IgG, and anti-EBV tests were relatively low (r = 0.73-0.77). Correlation coefficients for anti-TPO, prolactin, vitamin B12, and folate were also characterized with high values (r = 0.97-0.99). CONCLUSIONS: High accuracy and quantitative correlation were demonstrated between Ser-Col and samples collected by standard venipuncture. Hence, the Ser-Col blood collection device should be considered as a promising alternative for blood collection, storage, and transportation in both adult and pediatric populations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neuroscience Laboratory, Cobrain Center, Yerevan State Medical University named after Mkhitar Heratsi, Yerevan, Armenia.
- Department of Infectious Diseases, Yerevan State Medical University named after Mkhitar Heratsi, Yerevan, Armenia.
- Laboratory-Diagnostic Center of Heratsi Clinical Hospital, Yerevan State Medical University named after Mkhitar Heratsi, Yerevan, Armenia.
- Neuroscience Laboratory, Cobrain Center, Yerevan State Medical University named after Mkhitar Heratsi, Yerevan, Armenia; Department of Allergology and Clinical Immunology, Yerevan State Medical University named after Mk…
- Labonovum, Limmen, the Netherlands.
- Pathogenesis and Control of Chronic and Emerging Infections, Montpellier University, INSERM, Établissement Français du Sang, Antilles University, Montpellier University Hospital, Montpellier, France.
Förderung
- Science Committee of the Ministry of Education Science Culture and Sports of the Republic of Armenia
- Horizon 2020 European Innovation Council Fast Track to Innovation
Zitieren
APA
Harutyunyan, H., Hovhannisyan, A., Torosyan, H., Hakobjanyan, G., Grigoryan, A., Petrosyan, G., Movsisyan, M., Poland, D., Monkel, R., Lommen, J., Tuaillon, E., & Yenkoyan, K. (2025). Clinical performance and application of novel serum collection “Ser-Col” device in the practice of laboratory diagnosis of infection diseases and several other immunochemical tests. Clinica Chimica Acta. https://doi.org/10.1016/j.cca.2024.119970
Vancouver
Harutyunyan H, Hovhannisyan A, Torosyan H, Hakobjanyan G, Grigoryan A, Petrosyan G, et al. Clinical performance and application of novel serum collection “Ser-Col” device in the practice of laboratory diagnosis of infection diseases and several other immunochemical tests. Clinica Chimica Acta. 2025. doi:10.1016/j.cca.2024.119970
BibTeX
@article{Harutyunyan2025,
author = {Harutyunyan, Hayk and Hovhannisyan, Alvard and Torosyan, Hamlet and Hakobjanyan, Gohar and Grigoryan, Ani and Petrosyan, Gayane and Movsisyan, Mariam and Poland, Dennis and Monkel, Richard and Lommen, Joan and Tuaillon, Edouard and Yenkoyan, Konstantin},
title = {Clinical performance and application of novel serum collection “Ser-Col” device in the practice of laboratory diagnosis of infection diseases and several other immunochemical tests},
journal = {Clinica Chimica Acta},
year = {2025},
doi = {10.1016/j.cca.2024.119970}
}
EUVIMED