Coagulation factors VIII and factors IX testing practices in China: Results of the 5-year external quality assessment program
Clinica Chimica Acta · 2025
DOI: 10.1016/j.cca.2024.119950 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinica Chimica Acta, 2025. Verfasst von Chengshan Xu und 4 weiteren Autor:innen. Beteiligte Einrichtung: National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/ National Center of…. Hauptthemen laut MEDLINE: Factor IX, Factor VIII. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Beijing Hospital.
Abstract (Originalsprache)
BACKGROUND AND AIMS: Testing for coagulation factors VIII (FVIII) and IX (FIX) plays significant importance in the diagnostic and treatment of hemophilia A and B. External quality assessment (EQA) scheme aimed to assess the participants' performance of testing for coagulation factors and identify shortcomings in clinical practice. This study aimed to investigate the performance trends of the participating laboratories in China national external quality assessment Scheme (China NEQAS) for FVIII and FIX over a five-year period (2019-2023). MATERIALS AND METHODS: A total of ten external quality assessment (EQA) rounds were conducted from 2019 to 2023 in the China NEQAS for FVIII and FIX. The distribution of method, reagent and instrument were calculated. The trends of method- specific inter-laboratory coefficient of variation (CV) and pass rates were analyzed over 5 years. The dilutions for coagulation factor testing were also investigated. RESULTS: All laboratories use one-stage assays to detect FVIII and FIX activity. The inter-laboratory overall CV decreased year by year (10.9 % to 9.3 % for FVIII and 13.5 % to 10.2 % for FIX), and the laboratory pass rate steadily increased (88.0 % to 93.4 % for FVIII and 81.3 % to 92.7 % for FIX). The majority of laboratories employed a single dilution methodology for the assessment of FVIII and FIX activity. The interlaboratory CV was elevated for the Siemens reagent (Actin FSL) during analysis of moderately abnormal FIX concentrations of EQA samples in most batches. CONCLUSIONS: The implementation of the external quality assessment has contributed to facilitate the enhancement of testing quality. Chromogenic assay is a supplement to accurate determination when necessary. Laboratories may choose to perform dilution tests or direct assays to identify the presence of inhibitors, particularly when they are suspected.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/ National Center of Gerontology, PR China.
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/ National Center of Gerontology, PR China. Electronic address: cbli@nccl.org.cn.
Förderung
- Beijing Hospital
Zitieren
APA
Xu, C., Du, Z., Hu, G., Ma, Y., & Li, C. (2025). Coagulation factors VIII and factors IX testing practices in China: Results of the 5-year external quality assessment program. Clinica Chimica Acta. https://doi.org/10.1016/j.cca.2024.119950
Vancouver
Xu C, Du Z, Hu G, Ma Y, Li C. Coagulation factors VIII and factors IX testing practices in China: Results of the 5-year external quality assessment program. Clinica Chimica Acta. 2025. doi:10.1016/j.cca.2024.119950
BibTeX
@article{Xu2025,
author = {Xu, Chengshan and Du, Zhongli and Hu, Gaofeng and Ma, Yating and Li, Chenbin},
title = {Coagulation factors VIII and factors IX testing practices in China: Results of the 5-year external quality assessment program},
journal = {Clinica Chimica Acta},
year = {2025},
doi = {10.1016/j.cca.2024.119950}
}
EUVIMED