Hook-effect in MAGLUMI immunoassay for serum anti-GAD antibodies in neurological disorders: When “wrong” matrix is the right choice
Clinica Chimica Acta · 2024
DOI: 10.1016/j.cca.2024.119679 ↗Kurz gefasst
Fallbericht in der Zeitschrift Clinica Chimica Acta, 2024. Verfasst von G Musso und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine-DIMED, University of Padova, Padova, Italy; Laboratory Medicine Unit, University-Hospital of Padova, Padova, Italy. Electronic…. Hauptthemen laut MEDLINE: Glutamate Decarboxylase, Autoantibodies. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Antibodies against glutamic acid decarboxylase (anti-GAD) are a valuable diagnostic tool to detect severe autoimmune conditions as type 1 diabetes mellitus (T1DM) and anti-GAD related neurological disorders, having the latter more often anti-GAD concentrations in serum multiple times higher than in the former. Automated immunoassays, either with ELISA or chemiluminescent technology, are validated for diagnostic use in serum with analytical ranges suitable for T1DM diagnosis. In a patient presenting with a suspected autoimmune ataxia, anti-GAD testing on an automated chemiluminescent immunoassay (CLIA) resulted in slightly abnormal concentrations in serum (39.2 KIU/L) and very high concentrations in CSF (>280 KIU/L), thus prompting to proceed to serum dilutions to exclude a false negative result and a misdiagnosis. Different dilutions of serum resulted in nonlinear concentrations with endpoint result of 276,500 KIU/L at dilution 1:1000. CSF dilution was instead linear with endpoint result of 4050 KIU/L. In this case report we found that anti-GAD testing in CSF was essential to establish the clinical diagnosis and to suspect hook-effect in serum due to the excess of autoantibodies in this severe autoimmune condition.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Medicine-DIMED, University of Padova, Padova, Italy; Laboratory Medicine Unit, University-Hospital of Padova, Padova, Italy. Electronic address: giulia.musso@unipd.it.
- Neurology Unit, Ospedale Sant'Antonio, University-Hospital of Padova, Padova, Italy.
- Laboratory Medicine Unit, University-Hospital of Padova, Padova, Italy.
- Department of Medicine-DIMED, University of Padova, Padova, Italy; Laboratory Medicine Unit, University-Hospital of Padova, Padova, Italy.
Zitieren
APA
Musso, G., Zoccarato, M., Gallo, N., Plebani, M., & Basso, D. (2024). Hook-effect in MAGLUMI immunoassay for serum anti-GAD antibodies in neurological disorders: When “wrong” matrix is the right choice. Clinica Chimica Acta. https://doi.org/10.1016/j.cca.2024.119679
Vancouver
Musso G, Zoccarato M, Gallo N, Plebani M, Basso D. Hook-effect in MAGLUMI immunoassay for serum anti-GAD antibodies in neurological disorders: When “wrong” matrix is the right choice. Clinica Chimica Acta. 2024. doi:10.1016/j.cca.2024.119679
BibTeX
@article{Musso2024,
author = {Musso, G and Zoccarato, M and Gallo, N and Plebani, M and Basso, D},
title = {Hook-effect in MAGLUMI immunoassay for serum anti-GAD antibodies in neurological disorders: When “wrong” matrix is the right choice},
journal = {Clinica Chimica Acta},
year = {2024},
doi = {10.1016/j.cca.2024.119679}
}
EUVIMED