EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Reflex strategy to ensure accurate total testosterone results from consumer initiated, self-collected capillary samples

Anissa R Naranjo, Matthew D Krasowski, Amal Hamdan, Kristin O'Connor, Claire Carter, Joyce Chen, Dina N Greene

Clinica Chimica Acta · 2024

DOI: 10.1016/j.cca.2024.119676 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinica Chimica Acta, 2024. Verfasst von Anissa R Naranjo und 6 weiteren Autor:innen. Beteiligte Einrichtung: LetsGetChecked Laboratories, Monrovia, CA, United States. Hauptthemen laut MEDLINE: Testosterone, Luteinizing Hormone. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Self-collected capillary samples are convenient for direct access testing (DAT), but exogenous testosterone use may cause falsely elevated total testosterone (TT) results. We designed a quality assurance workflow to differentiate between accurate or erroneous supraphysiological TT concentrations. METHODS: Clinical samples with TT > 1500 ng/dL were reflexed to luteinizing hormone (LH) and follicle stimulating hormone (FSH) and screened for exogenous testosterone use. Samples (n = 120) with normal TT were reflexed to LH/FSH as a control. RESULTS: A total of 8572 TT samples were evaluated, of which 533 (6.2 %) had TT > 1500 ng/dL and were reflexed. Of these, 441 (82.7 %) had significantly decreased LH/FSH ( 1500 ng/dL, injectable exogenous testosterone use was most commonly accompanied by significantly decreased LH/FSH, while topical testosterone use was most commonly accompanied by detectable LH/FSH. Control samples were almost all (99.2 %) within or above the LH/FSH reference intervals. Unique patients ordered 351 TT tests where at least one TT result was > 1500 ng/dL. Based on TT and LH/FSH results, we hypothesized that patients were intermittently or consistently overusing exogenous testosterone, resolved elevated TT with recollection, or repeatedly contaminated their sample. CONCLUSION: Self-collected capillary specimens are acceptable for TT testing. A quality assurance reflex to LH/FSH can determine the validity of supraphysiological TT results in a consumer initiated/DAT population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TestosteroneLuteinizing HormoneHumansMaleFollicle Stimulating HormoneAdultMiddle AgedCapillariesFemaleBlood Specimen Collection

Stichwörter der Autor:innen

CapillaryConsumer initiated testingContaminationGonadotropinsTestosterone

Substanzen

TestosteroneLuteinizing HormoneFollicle Stimulating Hormone

Autor:innen und Institutionen

  • LetsGetChecked Laboratories, Monrovia, CA, United States.
  • University of Iowa, Department of Pathology, Iowa City, IA, United States.
  • LetsGetChecked Laboratories, Monrovia, CA, United States; University of Washington, Department of Laboratory Medicine and Pathology, Seattle, WA, United States. Electronic address: dngreene@uw.edu.

Zitieren

APA

Naranjo, A. R., Krasowski, M. D., Hamdan, A., O'Connor, K., Carter, C., Chen, J., & Greene, D. N. (2024). Reflex strategy to ensure accurate total testosterone results from consumer initiated, self-collected capillary samples. Clinica Chimica Acta. https://doi.org/10.1016/j.cca.2024.119676

Vancouver

Naranjo AR, Krasowski MD, Hamdan A, O'Connor K, Carter C, Chen J, et al. Reflex strategy to ensure accurate total testosterone results from consumer initiated, self-collected capillary samples. Clinica Chimica Acta. 2024. doi:10.1016/j.cca.2024.119676

BibTeX
@article{Naranjo2024,
  author = {Naranjo, Anissa R and Krasowski, Matthew D and Hamdan, Amal and O'Connor, Kristin and Carter, Claire and Chen, Joyce and Greene, Dina N},
  title = {Reflex strategy to ensure accurate total testosterone results from consumer initiated, self-collected capillary samples},
  journal = {Clinica Chimica Acta},
  year = {2024},
  doi = {10.1016/j.cca.2024.119676}
}
Kostenlos starten →