A novel way to evaluate autoantibody interference in samples with mixed antinuclear antibody patterns in the HEp-2 cell based indirect immunofluorescence assay and comparison of conventional microscopic and computer-aided pattern recognition
Clinica Chimica Acta · 2024
DOI: 10.1016/j.cca.2023.117747 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinica Chimica Acta, 2024. Verfasst von Gábor Nagy und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary. Hauptthemen laut MEDLINE: Antibodies, Antinuclear, Autoimmune Diseases. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Általános Orvostudományi Kar, Debreceni Egyetem, National Research Development and Innovation Office, University of Debrecen.
Abstract (Originalsprache)
BACKGROUND: A major challenge of the HEp-2 cell-based indirect immunofluorescence (IIF) assays is the correct identification of the individual anti-nuclear antibodies (ANAs) if more than one is present in a sample. We created artificial mixes by pooling two different samples with a single autoantibody in different titers. Comparison of the expected and observed patterns and titers clarifies the interference between the two tested ANAs. METHODS: Serum samples with a single homogeneous or speckled ANA pattern were serially diluted and mixed in 16 combinations, providing end-point titers of 1:5,120 to 1:80 for both patterns. These mixes were tested by a HEp-2 IIF assay and were evaluated by conventional evaluation, the EUROPattern (EPa) system and on-screen analysis. RESULTS: Homogeneous pattern can alter the identification of the speckled pattern much more than vice versa, but both has an interfering effect on the other. The effect of the interfering on the tested pattern was higher if the titer of the former one was higher. The pattern recognition efficacy of conventional and the on-screen evaluation was similar and superior compared to the EPa analysis. CONCLUSIONS: The application of artificial mixed samples can help the evaluation of the efficacy of manual and computer-aided ANA HEp-2 pattern recognition.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary.
- Institute of Internal Medicine, Department of Clinical Immunology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary.
- Institute of Internal Medicine, Department of Rheumatology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary.
- Department of Gastroenterology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary.
- Department of Gastroenterology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary; European Reference Network on Hepatological Diseases, ERN RARE-LIVER, Debrecen, Hungary.
- Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary. Electronic address: antalszp@med.unideb.hu.
Förderung
- Általános Orvostudományi Kar, Debreceni Egyetem
- National Research Development and Innovation Office
- University of Debrecen
- Nemzeti Kutatási, Fejlesztési és Innovaciós Alap
Zitieren
APA
Nagy, G., Földesi, R., Csípő, I., Tarr, T., Szűcs, G., Szántó, A., Bubán, T., Szekanecz, Z., Papp, M., Kappelmayer, J., & Antal-Szalmás, P. (2024). A novel way to evaluate autoantibody interference in samples with mixed antinuclear antibody patterns in the HEp-2 cell based indirect immunofluorescence assay and comparison of conventional microscopic and computer-aided pattern recognition. Clinica Chimica Acta. https://doi.org/10.1016/j.cca.2023.117747
Vancouver
Nagy G, Földesi R, Csípő I, Tarr T, Szűcs G, Szántó A, et al. A novel way to evaluate autoantibody interference in samples with mixed antinuclear antibody patterns in the HEp-2 cell based indirect immunofluorescence assay and comparison of conventional microscopic and computer-aided pattern recognition. Clinica Chimica Acta. 2024. doi:10.1016/j.cca.2023.117747
BibTeX
@article{Nagy2024,
author = {Nagy, Gábor and Földesi, Róza and Csípő, István and Tarr, Tünde and Szűcs, Gabriella and Szántó, Antónia and Bubán, Tamás and Szekanecz, Zoltán and Papp, Mária and Kappelmayer, János and Antal-Szalmás, Péter},
title = {A novel way to evaluate autoantibody interference in samples with mixed antinuclear antibody patterns in the HEp-2 cell based indirect immunofluorescence assay and comparison of conventional microscopic and computer-aided pattern recognition},
journal = {Clinica Chimica Acta},
year = {2024},
doi = {10.1016/j.cca.2023.117747}
}
EUVIMED