Quantitative analysis of soluble costimulatory molecules as potential diagnostic biomarkers for rheumatoid arthritis using LC-MS/MS in MRM mode
Clinica Chimica Acta · 2023
DOI: 10.1016/j.cca.2023.117501 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinica Chimica Acta, 2023. Verfasst von Abeer K Malkawi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Quebec at Montreal, Montreal, QC H3C3P8, Canada. Hauptthemen laut MEDLINE: CD28 Antigens, Arthritis, Rheumatoid. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 50 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND AND AIMS: Rheumatoid arthritis (RA) is a chronic autoimmune disease. RA-induced immunological responses are coordinated by T-cell stimulation. The costimulatory signal CD28-B7 is essential for T-cell activation by interacting CD28 with CD80 and CD86 costimulatory proteins. CTLA4 is another costimulatory protein that binds to CD80 and CD86 to inhibit T-cell activity. The soluble costimulatory proteins: sCD80, sCD86, sCD28, and sCTLA-4 were detected and quantified in human plasma and correlated with RA development. As potential diagnostic biomarkers for RA, developing a sensitive, specific, and reproducible method for quantifying these costimulatory molecules in human plasma and establishing quantitative ranges for each protein in healthy and RA patients' plasma is essential for advancing the clinical diagnostic and health outcomes. MATERIALS AND METHODS: A novel quantitative liquid chromatography-tandem spectrometry (LC-MS/MS) technique using multiple reaction monitoring (MRM) modes was developed and validated to measure soluble costimulatory molecules sCTLA4, sCD28, sCD80, and sCD86 in human plasma samples. Furthermore, the method was applied to determine sCTLA4, sCD28, sCD80, and sCD86 levels in plasma samples from RA patients (n = 23) and healthy controls (n = 21). RESULTS: The method was successfully developed and validated according to international inter- and intra-assay precision and accuracy guidelines. The linearity of the method was achieved between 0.5 nM and 100 nM for each protein with a correlation coefficient of > 0.998. The plasma level of sCTLA4, sCD80, and sCD86 in RA patients was significantly elevated compared to controls. RA patients had 63.32 ± 17.63 nM sCTLA4 and controls 36.05 ± 18.83 nM; p < 0.0001. The performance of the four proteins was determined using ROC curves, where sCTLA4 showed the highest diagnostic and clinical performance compared to the others. CONCLUSIONS: This study reports the first use of LC-MS/MS in MRM mode to accurately quantify soluble costimulatory molecules in plasma samples as potential RA diagnostic biomarkers. Determination of the reference range for each protein with high selectivity and sensitivity increases the potential for utilizing this method as a clinical diagnostic.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, University of Quebec at Montreal, Montreal, QC H3C3P8, Canada.
- Department of Medical Laboratory Sciences, Jordan University of Science and Technology, Irbid 22110, Jordan.
- Metabolomics Section, Department of Clinical Genomics, Center for Genomics Medicine, King Faisal Specialist Hospital and Research Centre (KFSHRC), Riyadh 11211, Saudi Arabia.
- Department of Medicine, Rheumatology Unit, College of Medicine, King Saud University, Riyadh, Saudi Arabia.
- Proteomics Resource Unit, Obesity Research Center, College of Medicine, King Saud University, P.O. Box 2925 (98), Riyadh 11461, Saudi Arabia.
- Metabolomics Section, Department of Clinical Genomics, Center for Genomics Medicine, King Faisal Specialist Hospital and Research Centre (KFSHRC), Riyadh 11211, Saudi Arabia; Department of Biochemistry and Molecular Med…
Zitieren
APA
Malkawi, A. K., Nimer, R. M., Almogren, M., Masood, A., Alarfaj, A. S., Benabdelkamel, H., Abdel Rahman, A. M., & Siaj, M. (2023). Quantitative analysis of soluble costimulatory molecules as potential diagnostic biomarkers for rheumatoid arthritis using LC-MS/MS in MRM mode. Clinica Chimica Acta. https://doi.org/10.1016/j.cca.2023.117501
Vancouver
Malkawi AK, Nimer RM, Almogren M, Masood A, Alarfaj AS, Benabdelkamel H, et al. Quantitative analysis of soluble costimulatory molecules as potential diagnostic biomarkers for rheumatoid arthritis using LC-MS/MS in MRM mode. Clinica Chimica Acta. 2023. doi:10.1016/j.cca.2023.117501
BibTeX
@article{Malkawi2023,
author = {Malkawi, Abeer K and Nimer, Refat M and Almogren, Maha and Masood, Afshan and Alarfaj, Abdulrahman S and Benabdelkamel, Hicham and Abdel Rahman, Anas M and Siaj, Mohamed},
title = {Quantitative analysis of soluble costimulatory molecules as potential diagnostic biomarkers for rheumatoid arthritis using LC-MS/MS in MRM mode},
journal = {Clinica Chimica Acta},
year = {2023},
doi = {10.1016/j.cca.2023.117501}
}
EUVIMED