Wearable Accelerometer-Derived Measures of Physical Activity in Heart Failure: Insights From the DETERMINE trials
Journal of Cardiac Failure · 2025-04 · 31 (4) · 689-703
DOI: 10.1016/j.cardfail.2024.10.439 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Journal of Cardiac Failure, 2025-04. Verfasst von Kieran F Docherty und 15 weiteren Autor:innen. Beteiligte Einrichtung: BHF Cardiovascular Research Centre, University of Glasgow, Glasgow, UK. Hauptthemen laut MEDLINE: Heart Failure, Accelerometry, Exercise, Wearable Electronic Devices. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: AstraZeneca in Gothenburg, AstraZeneca, British Heart Foundation.
Themen: Herzinsuffizienz
Abstract (Originalsprache)
INTRODUCTION: Wearable accelerometers allow continuous assessment of physical activity during normal living conditions and may be useful in evaluating the effects of treatment for heart failure. We explored the relationships between accelerometer measures of physical activity and 6-minute walk distance and patient-reported measures of functional limitation in participants across the entire spectrum of left ventricular ejection fraction in the DETERMINE (Dapagliflozin EffecT on ExeRcise capacity using a 6-MINutE walk test in patients with heart failure) trials. METHODS: A subgroup of patients in the DETERMINE trials wore a waist-based accelerometer during 7-day periods at 3 points during the trial: between screening and randomization and during weeks 8 and 14. Patients completed the Kansas City Cardiomyopathy Questionnaire (KCCQ) and 6-minute walk distance (6MWD) at baseline and at weeks 8 and 16. RESULTS: Of the 817 patients randomized, 319 (39%) had adequate baseline accelerometer data. Patients with lower levels of physical activity had lower (ie, worse) KCCQ scores and 6MWD, higher NT-proBNP levels and BMIs, worse kidney function, and a greater likelihood of diabetes and atrial fibrillation. Baseline accelerometer values had weak correlations with KCCQ summary scores (Pearson r = 0.06-0.21) and weak to moderate correlations with 6MWD (Pearson r = 0.20-0.31). The change from baseline to 16 weeks in accelerometer-measured physical activity correlated weakly with the change in KCCQ summary scores (Pearson r = 0-0.18) and 6MWD (r = 0.01-0.10). CONCLUSIONS: In the DETERMINE trials, accelerometer-based measures of physical activity correlated modestly with KCCQ summary scores and 6MWD. Accelerometer-based assessments of physical activity may provide additional information complementing that obtained from standard measures of functional limitation in patients with heart failure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- BHF Cardiovascular Research Centre, University of Glasgow, Glasgow, UK.
- Data Science, Late-Stage Development, Cardiovascular, Renal and Metabolic, BioPharmaceuticals R&D, AstraZeneca, Gothenburg, Sweden.
- HTA Statistics & Data Science, Biopharmaceuticals BBU, AstraZeneca, Barcelona, Spain.
- Department of Cardiology, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands.
- AstraZeneca BioPharmaceuticals Research & Development, Late-stage Development, Cardiovascular, Renal and Metabolic, Gaithersburg, MD, USA.
- Late Stage Development, Cardiovascular, Renal and Metabolism, BioPharmaceuticals Research & Development, AstraZeneca, Gothenburg, Sweden.
Förderung
- AstraZeneca in Gothenburg
- AstraZeneca
- British Heart Foundation
Zitieren
APA
Docherty, K. F., Buendia Lopez, R., Folkvaljon, F., Boer, R. A., Chen, J., Hammarstedt, A., Kitzman, D. W., Kosiborod, M. N., Langkilde, A. M., Reicher, B., Senni, M., Wilderäng, U., Verma, S., Cowie, M. R., Solomon, S. D., & McMurray, J. J. V. (2025). Wearable Accelerometer-Derived Measures of Physical Activity in Heart Failure: Insights From the DETERMINE trials. Journal of Cardiac Failure, 31(4), 689-703. https://doi.org/10.1016/j.cardfail.2024.10.439
Vancouver
Docherty KF, Buendia Lopez R, Folkvaljon F, Boer RA, Chen J, Hammarstedt A, et al. Wearable Accelerometer-Derived Measures of Physical Activity in Heart Failure: Insights From the DETERMINE trials. Journal of Cardiac Failure. 2025;31(4):689-703. doi:10.1016/j.cardfail.2024.10.439
BibTeX
@article{Docherty2025,
author = {Docherty, Kieran F and Buendia Lopez, Ruben and Folkvaljon, Folke and Boer, Rudolf A DE and Chen, Jersey and Hammarstedt, Ann and Kitzman, Dalane W and Kosiborod, Mikhail N and Langkilde, Anna Maria and Reicher, Barry and Senni, Michele and Wilderäng, Ulrica and Verma, Subodh and Cowie, Martin R and Solomon, Scott D and McMurray, John J V},
title = {Wearable Accelerometer-Derived Measures of Physical Activity in Heart Failure: Insights From the DETERMINE trials},
journal = {Journal of Cardiac Failure},
year = {2025},
volume = {31},
number = {4},
pages = {689--703},
doi = {10.1016/j.cardfail.2024.10.439}
}
EUVIMED