Cone-beam computed tomography-based radiomics for tumour regression assessment during radiotherapy of non-small-cell lung cancer

Fan Zhang, Xutong Li, Lu Yue, Yinglin Peng, Mi Zhou, Zhiping Luo

Cancer/Radiothérapie · 2026-04 · 30 (2) · 104809

DOI: 10.1016/j.canrad.2026.104809 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cancer/Radiothérapie, 2026-04. Verfasst von Fan Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Safety, China Institute of Atomic Energy, Beijing, China; Department of Radiation Oncology, Qingdao Municipal Hospital, Qingdao…. Hauptthemen laut MEDLINE: Radiomics, Carcinoma, Non-Small-Cell Lung, Cone-Beam Computed Tomography, Lung Neoplasms. Die Arbeit nennt 25 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: During radiotherapy of non-small-cell lung cancers, changes in radiomics features extracted from cone-beam computed tomography images can serve as unique predictors. For adapting treatment plans or assessing early treatment responses, there is a pressing need to screen cone-beam computed tomography-derived radiomics features for predicting tumour regression volume. PATIENTS AND METHODS: Our study enrolled 58 patients with non-small cell lung cancer undergoing radiotherapy, comprising dataset1, and an additional 32 patients who underwent an adaptive treatment approach, forming dataset2. For dataset1 patients, radiomics features were extracted from both the planning computed tomography and the first treatment cone-beam computed tomography. For dataset2 patients, features were also extracted from the replanning computed tomography and the corresponding cone-beam computed tomography after 20 fractions of radiotherapy. By employing correlation coefficient and intraclass correlation coefficient analyses on planning computed tomography and first treatment cone-beam computed tomography features, we identified robust and reproducible features in dataset1 patients. Reproducible delta radiomics features were further selected to characterize feature changes and screen delta radiomics features for tumour regression in dataset2 patients. Lastly, predictive delta radiomics features were screened using least absolute shrinkage and selection operator regression. RESULTS: Based on dataset1, we selected 34 radiomics features. From these, 16 delta radiomics features were further screened using dataset2. The changes observed in these features were consistent across both computed tomography and cone-beam computed tomography images. Specifically, nine features exhibited significant differences (p 0.05). Ultimately, four delta radiomics features were identified to classify tumour regression volume with a 30 % threshold for cone-beam computed tomography images. CONCLUSION: Our study introduces a novel strategy for selecting computed tomography-based cone-beam computed tomography radiomics features, enabling the identification of reliable features for model development. Preliminary findings firstly demonstrate the feasibility of using cone-beam computed tomography-based delta radiomics features to classify tumour regression volume during radiotherapy of non-small-cell lung cancer.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiomicsCarcinoma, Non-Small-Cell LungCone-Beam Computed TomographyLung NeoplasmsHumansFemaleMaleAgedMiddle AgedRadiotherapy Planning, Computer-AssistedTumor BurdenAged, 80 and over

Stichwörter der Autor:innen

CBCTCBNPCFeature selectionNSCLCRadiomicsRadiomiqueRémission tumoraleSélection de caractéristiquesTumour regression

Autor:innen und Institutionen

  • Department of Nuclear Safety, China Institute of Atomic Energy, Beijing, China; Department of Radiation Oncology, Qingdao Municipal Hospital, Qingdao, China.
  • Department of Radiation Oncology, Qingdao Municipal Hospital, Qingdao, China.
  • Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-sen University Cancer Center, Guangzhou, China.
  • Department of Nuclear Safety, China Institute of Atomic Energy, Beijing, China. Electronic address: luozhiping00@163.com.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, F., Li, X., Yue, L., Peng, Y., Zhou, M., & Luo, Z. (2026). Cone-beam computed tomography-based radiomics for tumour regression assessment during radiotherapy of non-small-cell lung cancer. Cancer/Radiothérapie, 30(2), 104809. https://doi.org/10.1016/j.canrad.2026.104809

Vancouver

Zhang F, Li X, Yue L, Peng Y, Zhou M, Luo Z. Cone-beam computed tomography-based radiomics for tumour regression assessment during radiotherapy of non-small-cell lung cancer. Cancer/Radiothérapie. 2026;30(2):104809. doi:10.1016/j.canrad.2026.104809

BibTeX
@article{Zhang2026,
  author = {Zhang, Fan and Li, Xutong and Yue, Lu and Peng, Yinglin and Zhou, Mi and Luo, Zhiping},
  title = {Cone-beam computed tomography-based radiomics for tumour regression assessment during radiotherapy of non-small-cell lung cancer},
  journal = {Cancer/Radiothérapie},
  year = {2026},
  volume = {30},
  number = {2},
  pages = {104809},
  doi = {10.1016/j.canrad.2026.104809}
}
Kostenlos starten →