Dosimetric feasibility study (“proof of concept”) of refractory ventricular tachycardia radioablation using proton minibeams
Cancer/Radiothérapie · 2024
DOI: 10.1016/j.canrad.2024.02.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cancer/Radiothérapie, 2024. Verfasst von P Loap und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, institut Curie, Paris, France. Hauptthemen laut MEDLINE: Protons, Proton Therapy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Fundação para a Ciência e a Tecnologia, European Research Council, Horizon 2020.
Abstract (Originalsprache)
PURPOSE: Preclinical data demonstrated that the use of proton minibeam radiotherapy reduces the risk of toxicity in healthy tissue. Ventricular tachycardia radioablation is an area under clinical investigation in proton beam therapy. We sought to simulate a ventricular tachycardia radioablation with proton minibeams and to demonstrate that it was possible to obtain a homogeneous coverage of an arrhythmogenic cardiac zone with this technique. MATERIAL AND METHODS: An arrhythmogenic target volume was defined on the simulation CT scan of a patient, localized in the lateral wall of the left ventricle. A dose of 25Gy was planned to be delivered by proton minibeam radiotherapy, simulated using a Monte Carlo code (TOPAS v.3.7) with a collimator of 19 0.4 mm-wide slits spaced 3mm apart. The main objective of the study was to obtain a plan ensuring at least 93% of the prescription dose in 93% of the planning target volume without exceeding 110% of the prescribed dose in the planning target volume. RESULTS: The average dose in the planning treatment volume in proton minibeam radiotherapy was 25.12Gy. The percentage of the planning target volume receiving 93% (V93%), 110% (V110%), and 95% (V95%) of the prescribed dose was 94.25%, 0%, and 92.6% respectively. The lateral penumbra was 6.6mm. The mean value of the peak-to-valley-dose ratio in the planning target volume was 1.06. The mean heart dose was 2.54Gy versus 5.95Gy with stereotactic photon beam irradiation. CONCLUSION: This proof-of-concept study shows that proton minibeam radiotherapy can achieve a homogeneous coverage of an arrhythmogenic cardiac zone, reducing the dose at the normal tissues. This technique, ensuring could theoretically reduce the risk of late pulmonary and breast fibrosis, as well as cardiac toxicity as seen in previous biological studies in proton minibeam radiotherapy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiation Oncology, institut Curie, Paris, France.
- Signalisation radiobiologie et cancer, Inserm U1021, CNRS UMR3347, Institut Curie, université PSL, 91400 Orsay, France; Laboratório de Instrumentação e Física Experimental de Partículas (LIP), Lisboa, Portugal; Departam…
- Department of Anesthesia and Reanimation, institut Curie, Paris, France.
- Laboratório de Instrumentação e Física Experimental de Partículas (LIP), Lisboa, Portugal; Departamento de Física, Faculdade de Ciências, Universidade de Lisboa, Lisboa, Portugal.
- Signalisation radiobiologie et cancer, Inserm U1021, CNRS UMR3347, Institut Curie, université PSL, 91400 Orsay, France.
- Department of Radiation Oncology, institut Curie, Paris, France; Université Versailles, Saint-Quentin, France. Electronic address: youlia.kirova@curie.fr.
Förderung
- Fundação para a Ciência e a Tecnologia
- European Research Council
- Horizon 2020
Zitieren
APA
Loap, P., Giorgi, M., Vu-Bezin, J., Kirov, K., Sampai, J. M., Prezado, Y., & Kirova, Y. (2024). Dosimetric feasibility study (“proof of concept”) of refractory ventricular tachycardia radioablation using proton minibeams. Cancer/Radiothérapie. https://doi.org/10.1016/j.canrad.2024.02.002
Vancouver
Loap P, Giorgi M, Vu-Bezin J, Kirov K, Sampai JM, Prezado Y, et al. Dosimetric feasibility study (“proof of concept”) of refractory ventricular tachycardia radioablation using proton minibeams. Cancer/Radiothérapie. 2024. doi:10.1016/j.canrad.2024.02.002
BibTeX
@article{Loap2024,
author = {Loap, P and Giorgi, M and Vu-Bezin, J and Kirov, K and Sampai, J M and Prezado, Y and Kirova, Y},
title = {Dosimetric feasibility study (“proof of concept”) of refractory ventricular tachycardia radioablation using proton minibeams},
journal = {Cancer/Radiothérapie},
year = {2024},
doi = {10.1016/j.canrad.2024.02.002}
}
EUVIMED