EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Portable air cleaners in neonatal facilities: Hybrid experimental-CFD assessment of different configurations

Yik Chirt Teoh, Sasan Sadrizadeh, Erik Senneby, Jakob Löndahl, Annika Gram

Building and Environment · 2027-01 · 307 · 115381

DOI: 10.1016/j.buildenv.2026.115381 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Building and Environment, 2027-01. Verfasst von Yik Chirt Teoh und 4 weiteren Autor:innen. Die Arbeit nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Vetenskapsrådet, Region Skåne, Formas.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Neonates are highly vulnerable to airborne infections, and respiratory illnesses remain a major cause of morbidity and mortality in neonatal facilities. Portable air cleaners (PACs) are increasingly used to reduce indoor particle concentrations, yet evidence remains limited on how different PAC configurations affect their performance. This study combines long‑term onsite measurements in a neonatal patient room with computational fluid dynamics (CFD) simulations to evaluate different PAC configurations. Field measurements of particle concentrations were used to validate a detailed CFD model. The validated CFD model was then applied to investigate PAC placement, number of units, and clean air delivery rate (CADR). An additional case examined the effect of placing PAC under a table to reflect realistic space constraints. Both onsite measurements and CFD simulations consistently showed that PAC deployment reduced particle concentrations. Among the single‑unit configurations, placing the PAC at the centre of the room achieved the greatest reduction, lowering the normalised particle concentration by 58.6% compared with the no-PAC baseline case. Doubling the CADR at this centre location further improved removal performance but introduced higher noise levels. Two‑PAC configurations with higher combined CADR provided only marginal improvements over the optimal single‑PAC configuration. Locating the PAC underneath a table did not noticeably degrade performance. Overall, these findings highlight that PAC performance in neonatal facilities depends strongly on strategic placement and operating conditions.

Förderung

  • Vetenskapsrådet
  • Region Skåne
  • Formas
  • AFA Försäkring
  • Svenska Forskningsrådet Formas

Zitieren

APA

Teoh, Y. C., Sadrizadeh, S., Senneby, E., Löndahl, J., & Gram, A. (2027). Portable air cleaners in neonatal facilities: Hybrid experimental-CFD assessment of different configurations. Building and Environment, 307, 115381. https://doi.org/10.1016/j.buildenv.2026.115381

Vancouver

Teoh YC, Sadrizadeh S, Senneby E, Löndahl J, Gram A. Portable air cleaners in neonatal facilities: Hybrid experimental-CFD assessment of different configurations. Building and Environment. 2027;307:115381. doi:10.1016/j.buildenv.2026.115381

BibTeX
@article{Teoh2027,
  author = {Teoh, Yik Chirt and Sadrizadeh, Sasan and Senneby, Erik and Löndahl, Jakob and Gram, Annika},
  title = {Portable air cleaners in neonatal facilities: Hybrid experimental-CFD assessment of different configurations},
  journal = {Building and Environment},
  year = {2027},
  volume = {307},
  pages = {115381},