EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Evaluating indoor aerosol concentrations and size distributions under varying individual behaviors, ventilation and air purifier conditions

Arya Toghraei, Djordje Romanic

Building and Environment · 2025-09 · 283 · 113335

DOI: 10.1016/j.buildenv.2025.113335 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Building and Environment, 2025-09. Verfasst von Arya Toghraei und 1 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 82 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Quebec Research Fund Nature and Technology, Canadian Institutes of Health Research, McGill University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantifying aerosol concentrations in indoor environments is essential for mitigating airborne transmission of respiratory pathogens. This study aimed to characterize the effects of speaking, mask use, and gender on aerosol concentrations in a controlled chamber, and to assess mitigation strategies in a typical shared space. In a controlled 12 m³ chamber, six participants (three males, three females) completed four 20 min sessions—natural breathing and reading aloud, each with and without a surgical mask. Aerosol size-resolved concentrations (0.25–33 µm) were measured every 6 s using an optical particle counter. A mixed-effects model applied at the 5 % significance level showed that speaking increased concentrations by 26 % ( p < 0.001), while surgical masks reduced it by 63 % ( p < 0.001). Male participants emitted 38 % more aerosols than females, though the difference was not statistically significant ( p = 0.079). A two-mode lognormal model revealed a dominant submicron mode (Count Median Diameters (CMD) = 0.20–0.24 µm) and a secondary mode (CMD = 1.97–2.45 µm), consistent with lower and upper respiratory tract origins. Most particles fell in the submicron range. To evaluate broader implications, a complementary study was conducted in a 31.2 m³ graduate student office with four occupants under ten scenarios combining ventilation, air purification, and mask use. Without ventilation, CO₂ exceeded 1000 ppm within 20 min. The air purifier reduced aerosol concentrations, especially in the submicron range, while ventilation effectively controlled CO₂. Mask use had limited impact in this setting, where movement and surface activity dominated concentrations. These findings highlight the importance of concurrently implementing ventilation and air purification to manage aerosol and CO₂ levels in shared indoor environments.

Förderung

  • Quebec Research Fund Nature and Technology
  • Canadian Institutes of Health Research
  • McGill University
  • Institute of Population and Public Health

Zitieren

APA

Toghraei, A., & Romanic, D. (2025). Evaluating indoor aerosol concentrations and size distributions under varying individual behaviors, ventilation and air purifier conditions. Building and Environment, 283, 113335. https://doi.org/10.1016/j.buildenv.2025.113335

Vancouver

Toghraei A, Romanic D. Evaluating indoor aerosol concentrations and size distributions under varying individual behaviors, ventilation and air purifier conditions. Building and Environment. 2025;283:113335. doi:10.1016/j.buildenv.2025.113335

BibTeX
@article{Toghraei2025,
  author = {Toghraei, Arya and Romanic, Djordje},
  title = {Evaluating indoor aerosol concentrations and size distributions under varying individual behaviors, ventilation and air purifier conditions},
  journal = {Building and Environment},
  year = {2025},
  volume = {283},
  pages = {113335},
  doi = {10.1016/j.buildenv.2025.113335}
}
Kostenlos starten →