EUVIMEDEUVIMED entdecken
Crossref

Reliability-aware dual-representation DCE-MRI segmentation with disagreement-guided quality control for breast tumor delineation

Chih Mao Tsai, Jiann-Der Lee

Biomedical Signal Processing and Control · 2027-02 · 130 · 111588

DOI: 10.1016/j.bspc.2026.111588 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Signal Processing and Control, 2027-02. Verfasst von Chih Mao Tsai und 1 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Gefördert von: National Science and Technology Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Automated breast tumor segmentation on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) may support quantitative imaging analysis, but case-level segmentation failures remain a concern in heterogeneous multicenter data. We evaluated a reliability-aware dual-representation framework using the MAMA-MIA dataset. Five-fold out-of-fold (OOF) predictions from the 1,200-case development cohort were used exclusively to calibrate low-confidence burden (LCB)-based quality-control (QC) rules, which were then applied unchanged to final predictions from a separate 306-case held-out cohort. Raw3P used the pre-contrast and two post-contrast phases, whereas Sub513 used the pre-contrast phase and two subtraction maps. Separate nnU-Net v2 models were trained, and the binary-intersection ensemble was evaluated as a conservative consensus segmentation strategy. The resulting binary-intersection mask achieved mean Dice 0.763, precision 0.786, recall 0.814, 95th-percentile Hausdorff distance 40.16 mm, average symmetric surface distance 11.70 mm, normalized surface Dice at 2 mm 0.769, and absolute relative volume error 74.9%. Compared with the probability-averaging ensemble, the mean Dice gain was modest (0.0044; paired bootstrap 95% CI, 0.0013 to 0.0075), while recall decreased by 0.0166. At the frozen 40%-OOF-targeted point, 159/306 cases (52.0%) were referred for review, including 33/35 poor-quality masks (94.3%); the two missed poor-quality masks were false-negative QC cases among the 147 cases not referred. Dual-representation outputs therefore provided a useful case-level QC signal, but not a fail-safe or fully autonomous segmentation system.

Förderung

  • National Science and Technology Council

Zitieren

APA

Tsai, C. M., & Lee, J. (2027). Reliability-aware dual-representation DCE-MRI segmentation with disagreement-guided quality control for breast tumor delineation. Biomedical Signal Processing and Control, 130, 111588. https://doi.org/10.1016/j.bspc.2026.111588

Vancouver

Tsai CM, Lee J. Reliability-aware dual-representation DCE-MRI segmentation with disagreement-guided quality control for breast tumor delineation. Biomedical Signal Processing and Control. 2027;130:111588. doi:10.1016/j.bspc.2026.111588

BibTeX
@article{Tsai2027,
  author = {Tsai, Chih Mao and Lee, Jiann-Der},
  title = {Reliability-aware dual-representation DCE-MRI segmentation with disagreement-guided quality control for breast tumor delineation},
  journal = {Biomedical Signal Processing and Control},
  year = {2027},
  volume = {130},
  pages = {111588},
  doi = {10.1016/j.bspc.2026.111588}
}
Kostenlos starten →