Alzheimer’s disease classification using dynamic geometric pattern map: A novel image representation of EEG signals
Biomedical Signal Processing and Control · 2027-02 · 130 · 111554
DOI: 10.1016/j.bspc.2026.111554 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Signal Processing and Control, 2027-02. Verfasst von Hesam Akbari und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Demenz
Abstract (Originalsprache)
Electroencephalography (EEG) offers a non-invasive and low-cost basis for computer-aided dementia detection, but existing systems face limitations: data-dependent feature representations, deep models that process channels independently and discard inter-channel spatial topology, and optimistic accuracy from segment-level k-fold cross-validation (CV) that may collapse under subject-independent validation. This study introduces the Dynamic Geometric Pattern Map (DGPM), a parameter-free image representation of multichannel EEG. For each channel, fifteen geometrical features are extracted from the second-order difference plot (SODP) to quantify nonlinear dynamics without embedding, delay, or decomposition parameters. Features from all 19 channels are arranged into a single image preserving the 10–20 spatial arrangement. DGPM images were classified with five ImageNet-pretrained backbones on three binary tasks (AD vs. NC, FTD vs. NC, and AD vs. FTD) under 10-fold and leave-one-subject-out (LOSO) CV using 5-second segments. Under LOSO CV, accuracies were 69.23%, 75.00%, and 64.41%, respectively, with bootstrap 95% confidence intervals spanning approximately 12% on either side, whereas all binary accuracies exceeded 96% under 10-fold CV, revealing 24%–35% optimism from segment-level partitioning. Three-class LOSO accuracy reached 60.23%, significantly above uniform chance and majority-class rates. DGPM significantly outperformed five time–frequency image representations (Wilcoxon signed-rank test, Holm-adjusted p < 0.001 ), while performing comparably to conventional classifiers using the same handcrafted features. Permutation importance and Grad-CAM identified temporal, central, and frontal regions as informative, confirming that network decisions were driven by DGPM cell values rather than resizing artefacts. DGPM provides a compact, parameter-free, and interpretable EEG representation, although external multicenter validation remains necessary before clinical use.
Zitieren
APA
Akbari, H., Azadnouran, A., Sadiq, M. T., Siuly, S., Ghaderpour, E., & Mete, M. (2027). Alzheimer’s disease classification using dynamic geometric pattern map: A novel image representation of EEG signals. Biomedical Signal Processing and Control, 130, 111554. https://doi.org/10.1016/j.bspc.2026.111554
Vancouver
Akbari H, Azadnouran A, Sadiq MT, Siuly S, Ghaderpour E, Mete M. Alzheimer’s disease classification using dynamic geometric pattern map: A novel image representation of EEG signals. Biomedical Signal Processing and Control. 2027;130:111554. doi:10.1016/j.bspc.2026.111554
BibTeX
@article{Akbari2027,
author = {Akbari, Hesam and Azadnouran, Amir and Sadiq, Muhammad Tariq and Siuly, Siuly and Ghaderpour, Ebrahim and Mete, Mutlu},
title = {Alzheimer’s disease classification using dynamic geometric pattern map: A novel image representation of EEG signals},
journal = {Biomedical Signal Processing and Control},
year = {2027},
volume = {130},
pages = {111554},
doi = {10.1016/j.bspc.2026.111554}
}
EUVIMED