Development of a long-term AI-enabled monitoring device using reliable non-contact sensors for sleep apnea
Biomedical Signal Processing and Control · 2026-12 · 128 · 111334
DOI: 10.1016/j.bspc.2026.111334 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Signal Processing and Control, 2026-12. Verfasst von Tae Hwan Han und 4 weiteren Autor:innen. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Yonsei University College of Medicine.
Abstract (Originalsprache)
In this prospective observational study, we developed and validated a contactless diagnostic system combining 60-GHz frequency-modulated continuous-wave (FMCW) radar with artificial intelligence (AI) for obstructive sleep apnea (OSA) detection and evaluated it against polysomnography (PSG). Eighty-two adults (aged 18–65 years) underwent overnight PSG for suspected OSA with simultaneous 60-GHz radar monitoring of thoracoabdominal movement and autonomic surrogates. Radar signals were processed into respiratory and heart rate variability features and analyzed using convolutional neural networks and a random forest. The resulting probabilities were combined through an unweighted ensemble; before analysis, a consensus quality-control step excluded segments that all three streams failed to classify confidently. We assessed agreement with PSG using the intraclass correlation coefficient (ICC) and Bland–Altman analysis. We evaluated patient-level performance at apnea–hypopnea index (AHI) thresholds of 5, 15, and 30 events/h and across four severity tiers. Radar-derived AHI correlated with PSG-derived AHI (r = 0.80; p < 0.001; ICC = 0.80), with a mean bias of − 2.7 events/h and 95 % limits of agreement from − 38.1 to + 32.7 events/h. For severe OSA (AHI ≥ 30), sensitivity was 82.9 % and specificity 97.6 %; severity cross-classification achieved 64.6 % exact-tier and 93.9 % within-one-tier agreement (linear weighted κ = 0.60). The ensemble reached a segment-level accuracy of 82.7 %, a macro-F1 of 0.796, and an AUROC of 0.902 across a continuous 0.5–1.5 m operating range. Therefore, an AI-augmented, contactless FMCW radar can provide reliable segment-level detection and useful patient-level severity estimates, and they support its further development as a home-based tool for OSA screening and longitudinal follow-up in populations that current testing underserves.
Förderung
- Yonsei University College of Medicine
Zitieren
APA
Han, T. H., Jung, K., Shin, J., Ahn, J., & Chae, K. Y. (2026). Development of a long-term AI-enabled monitoring device using reliable non-contact sensors for sleep apnea. Biomedical Signal Processing and Control, 128, 111334. https://doi.org/10.1016/j.bspc.2026.111334
Vancouver
Han TH, Jung K, Shin J, Ahn J, Chae KY. Development of a long-term AI-enabled monitoring device using reliable non-contact sensors for sleep apnea. Biomedical Signal Processing and Control. 2026;128:111334. doi:10.1016/j.bspc.2026.111334
BibTeX
@article{Han2026,
author = {Han, Tae Hwan and Jung, Kisub and Shin, Jung-Won and Ahn, Jae-Cheul and Chae, Kyu Young},
title = {Development of a long-term AI-enabled monitoring device using reliable non-contact sensors for sleep apnea},
journal = {Biomedical Signal Processing and Control},
year = {2026},
volume = {128},
pages = {111334},
doi = {10.1016/j.bspc.2026.111334}
}
EUVIMED