Efficient sEMG decoding with hybrid, multi-timescale neural networks
Biomedical Signal Processing and Control · 2026-12 · 128 · 111215
DOI: 10.1016/j.bspc.2026.111215 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Signal Processing and Control, 2026-12. Verfasst von Andrea Ortone und 6 weiteren Autor:innen. Die Arbeit nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministero della Salute, European Commission, STMicroelectronics.
Abstract (Originalsprache)
Surface electromyography (sEMG) offers a non-invasive window into neuromuscular activity and is increasingly used as a reliable control signal for prosthetics, rehabilitation devices, and wearable health monitoring.However, decoding sEMG for such applications is computationally expensive, which remains a major barrier to deployment on embedded and wearable systems.To overcome this limitation, we introduce novel multi-timescale architectures for large-scale, continuous sEMG decoding.We first show that structured linear state-space models (SSMs), originally developed for long-sequence modeling, provide an efficient baseline for sEMG decoding on the emg2qwerty benchmark.These surpass state-of-the-art, transformer-based performance while requiring up to three orders of magnitude fewer operations.Building on this result, we introduce a hybrid multi-timescale architecture for the same large-scale sEMG decoding task, integrating linear SSMs, convolutional and event-driven networks within a structured two-stage framework.Our results show that the proposed homogeneous SSMs are optimal at high computational budgets (< 100 M MACs/s), whereas the introduced two-stage models substantially improve accuracy–efficiency scaling in the computationally constrained regimes relevant for edge deployment.In this regime, our two-stage models match or exceed prior state-of-the-art accuracy with up to 5000× lower computational cost.Finally, to demonstrate real-time operation in both distributed and end-to-end edge implementations, we deploy our best models on low-power STM32 microcontrollers, validating analytical complexity estimates against measured latencies.Overall, these results demonstrate that task-aligned, computationally efficient architectures enable real-time sEMG decoding on edge devices for naturalistic, dexterous motor control, paving the way towards effective prosthetics and rehabilitation devices, and wearable assistive and augmentative technologies.
Förderung
- Ministero della Salute
- European Commission
- STMicroelectronics
- Ministero dell’Istruzione, dell’Università e della Ricerca
- Erasmus Plus
Zitieren
APA
Ortone, A., Fabre, M., Massa, R., Mazzoni, A., Desoli, G., Oddo, C. M., & Neftci, E. (2026). Efficient sEMG decoding with hybrid, multi-timescale neural networks. Biomedical Signal Processing and Control, 128, 111215. https://doi.org/10.1016/j.bspc.2026.111215
Vancouver
Ortone A, Fabre M, Massa R, Mazzoni A, Desoli G, Oddo CM, et al. Efficient sEMG decoding with hybrid, multi-timescale neural networks. Biomedical Signal Processing and Control. 2026;128:111215. doi:10.1016/j.bspc.2026.111215
BibTeX
@article{Ortone2026,
author = {Ortone, Andrea and Fabre, Maxime and Massa, Riccardo and Mazzoni, Alberto and Desoli, Giuseppe and Oddo, Calogero Maria and Neftci, Emre},
title = {Efficient sEMG decoding with hybrid, multi-timescale neural networks},
journal = {Biomedical Signal Processing and Control},
year = {2026},
volume = {128},
pages = {111215},
doi = {10.1016/j.bspc.2026.111215}
}
EUVIMED