EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Reconstructing 12-lead ECG from reduced lead sets using an encoder–decoder convolutional neural network

Dorsa EPMoghaddam iD, Anton Banta, Allison Post, Mehdi Razavi, Behnaam Aazhang

Biomedical Signal Processing and Control · 2025-06 · 104 · 107486

DOI: 10.1016/j.bspc.2024.107486 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Signal Processing and Control, 2025-06. Verfasst von Dorsa EPMoghaddam und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, Rice University, United States of America. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NHLBI NIH HHS, National Heart, Lung, and Blood Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The standard 12-lead electrocardiogram (ECG) is the gold-standard clinical tool for assessing the heart's electrical activity. The primary goal of this study is to reduce the number of recording sites needed to capture the same amount of information as a 12-lead ECG. This approach will simplify monitoring procedures, improve patient comfort, and broaden ECG accessibility across various healthcare settings. In this work, a patient-specific framework is investigated to map a multivariate input to a multivariate output, namely reconstructing the standard 12-lead ECG from any subset of three independent standard ECG leads (i.e. I , I I , V 1 ∶ V 6 ).The algorithm is evaluated on two datasets: non-public data from 15 patients and the PTB Diagnostic ECG Database, with models trained and tested individually for each patient. The proposed method involves a series of preprocessing steps aimed at eliminating noise and segmenting the data into heartbeats, followed by Short-Time Fourier Transform (STFT) and an encoder-decoder convolutional neural network (CNN) model. The calculated correlation coefficient (CC) and root mean square error (RMSE) confirm the model's accuracy in reconstructing the 12-lead ECG. The proposed model achieves average correlations of 97.6% for the first dataset and 98.9% for the PTB Database using three leads. With a single lead as input, the average correlations reach 97.3% and 98.4% for the respective datasets. These results demonstrate the effectiveness of the proposed methodology in accurately reconstructing 12-lead ECGs using either any three independent leads or any single lead as input.

Schlagwörter

Stichwörter der Autor:innen

Cardiovascular diseasesConvolutional neural network (CNN)ECG reconstructionElectrocardiogram (ECG)Encoder–decoderMutual informationStandard 12-lead system

Autor:innen und Institutionen

  • Department of Electrical and Computer Engineering, Rice University, United States of America.
  • Electrophysiology Clinical Research and Innovations, Texas Heart Institute, United States of America.
  • Department of Cardiology, Texas Heart Institute, United States of America.

ORCID-Profile: Dorsa EPMoghaddam

Förderung

  • NHLBI NIH HHS
  • National Heart, Lung, and Blood Institute

Zitieren

APA

EPMoghaddam, D., Banta, A., Post, A., Razavi, M., & Aazhang, B. (2025). Reconstructing 12-lead ECG from reduced lead sets using an encoder–decoder convolutional neural network. Biomedical Signal Processing and Control, 104, 107486. https://doi.org/10.1016/j.bspc.2024.107486

Vancouver

EPMoghaddam D, Banta A, Post A, Razavi M, Aazhang B. Reconstructing 12-lead ECG from reduced lead sets using an encoder–decoder convolutional neural network. Biomedical Signal Processing and Control. 2025;104:107486. doi:10.1016/j.bspc.2024.107486

BibTeX
@article{EPMoghaddam2025,
  author = {EPMoghaddam, Dorsa and Banta, Anton and Post, Allison and Razavi, Mehdi and Aazhang, Behnaam},
  title = {Reconstructing 12-lead ECG from reduced lead sets using an encoder–decoder convolutional neural network},
  journal = {Biomedical Signal Processing and Control},
  year = {2025},
  volume = {104},
  pages = {107486},
  doi = {10.1016/j.bspc.2024.107486}
}