EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A reproducible safety assessment model for concurrent transcranial magnetic stimulation with implanted intracranial electroencephalography electrodes

Andrew Chang, Jakob Michiels, Gustavo Campos, Younghoon Nho, Romain Duprat, Nikolaos Vardalakis, Ashley Koluda, Liming Qiu, Wonkyung Choi, Robert Seilheimer, Taneeta M Ganguly, Roy H Hamilton und 5 weitere

Brain Stimulation · 2026-11 · 19 (6) · 103238

DOI: 10.1016/j.brs.2026.103238 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Brain Stimulation, 2026-11. Verfasst von Andrew Chang und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA. Hauptthemen laut MEDLINE: Transcranial Magnetic Stimulation, Electrodes, Implanted, Electroencephalography, Brain. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: University of Pennsylvania Perelman School of Medicine, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Concurrent transcranial magnetic stimulation and intracranial EEG (TMS-sEEG) offers a powerful approach for interrogating human brain circuits with high spatiotemporal resolution. However, standardized safety testing procedures for TMS in the presence of implanted electrodes are lacking. OBJECTIVE: To establish and validate a reproducible methodological framework for assessing TMS safety with sEEG hardware, addressing potential risks of electrode displacement, heating, and secondary current induction. METHODS: A conductive agarose phantom implanted with clinical-grade platinum sEEG electrodes was exposed to single-pulse TMS (0.4 Hz), repetitive TMS (1-50 Hz), and intermittent theta burst stimulation. Electrode displacement was quantified via high-speed video and motion tracking. Temperature changes were measured with fiber-optic thermal probes positioned at stimulated electrode contacts. Induced voltages were recorded using an oscilloscope and intracranial EEG hardware, and secondary current and charge density were calculated from oscilloscope outputs and impedance measurements. RESULTS: sEEG lead displacement remained micrometer-scale across stimulation conditions, with a maximum transient displacement of 10.99 μm and a maximum 1-s mean displacement from the pre-TMS position of 16.27 μm. Temperature changes remained well within the 2°C safety threshold across all tested conditions; in the primary temperature series, the maximum observed increase was 0.073°C. Induced voltages and charge densities remained below established safety limits, exhibiting consistent exponential decay with increasing distance from the coil. All stimulation conditions, including those exceeding typical clinical ranges, remained well within safety margins. CONCLUSIONS: Under the tested conditions in a controlled phantom environment, TMS exposure produced micrometer-scale transient and longer-timescale displacement, temperature changes within established safety thresholds, and charge densities within established safety thresholds. This validated methodological pipeline provides a standardized framework for future safety experiments involving TMS and implanted devices and supports continued development of TMS-sEEG as a tool for studying human brain circuitry and neuromodulation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcranial Magnetic StimulationElectrodes, ImplantedElectroencephalographyBrainElectrocorticographyHumansPhantoms, ImagingReproducibility of Results

Autor:innen und Institutionen

  • Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
  • Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA; Center for Neuroengineering and Therapeutics, University of Pennsylvania, PA, USA; Center for Neurotrauma, Neurodegeneration, and Restorat…
  • Center for the Neuromodulation of Depression and Stress, University of Pennsylvania, Perelman School of Medicine, Department of Psychiatry, Philadelphia, PA, USA; Department of Psychiatry, Perelman School of Medicine, U…
  • Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA.
  • Department of Neurosurgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA; Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA.
  • Department of Psychiatry, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.

Förderung

  • University of Pennsylvania Perelman School of Medicine
  • National Institutes of Health

Zitieren

APA

Chang, A., Michiels, J., Campos, G., Nho, Y., Duprat, R., Vardalakis, N., Koluda, A., Qiu, L., Choi, W., Seilheimer, R., Ganguly, T. M., Hamilton, R. H., Barbosa, D. A. N., Scangos, K., Oathes, D., Halpern, C., & Vitale, F. (2026). A reproducible safety assessment model for concurrent transcranial magnetic stimulation with implanted intracranial electroencephalography electrodes. Brain Stimulation, 19(6), 103238. https://doi.org/10.1016/j.brs.2026.103238

Vancouver

Chang A, Michiels J, Campos G, Nho Y, Duprat R, Vardalakis N, et al. A reproducible safety assessment model for concurrent transcranial magnetic stimulation with implanted intracranial electroencephalography electrodes. Brain Stimulation. 2026;19(6):103238. doi:10.1016/j.brs.2026.103238

BibTeX
@article{Chang2026,
  author = {Chang, Andrew and Michiels, Jakob and Campos, Gustavo and Nho, Younghoon and Duprat, Romain and Vardalakis, Nikolaos and Koluda, Ashley and Qiu, Liming and Choi, Wonkyung and Seilheimer, Robert and Ganguly, Taneeta M and Hamilton, Roy H and Barbosa, Daniel A N and Scangos, Katherine and Oathes, Desmond and Halpern, Casey and Vitale, Flavia},
  title = {A reproducible safety assessment model for concurrent transcranial magnetic stimulation with implanted intracranial electroencephalography electrodes},
  journal = {Brain Stimulation},
  year = {2026},
  volume = {19},
  number = {6},
  pages = {103238},
  doi = {10.1016/j.brs.2026.103238}
}
Kostenlos starten →