EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-capacity transcranial direct current stimulation (HC-tDCS)

Kyle Donnery, Mohamad FallahRad, Santiago Osorio, Mojtaba Belali Koochesfahani, Niranjan Khadka, Matthew Saw, Jinglin Mo, Benjamin Babaev, Rayyan Bhuiyan, Jana M Elwassif, Marom Bikson

Brain Stimulation · 2026-11 · 19 (6) · 103233

DOI: 10.1016/j.brs.2026.103233 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Brain Stimulation, 2026-11. Verfasst von Kyle Donnery und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, The City College of New York, CUNY, New York, NY, USA. Electronic address: kdonnery@ccny.cuny.edu. Hauptthemen laut MEDLINE: Transcranial Direct Current Stimulation, Brain. Die Arbeit nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Enhancing tDCS technology can support the delivery of higher current intensities, enabling broader dose-response studies in human clinical trials. METHODS: High-Capacity tDCS (HC-tDCS) integrates novel electrodes and adaptive current/voltage controlled electronics. Multi-layer HC electrodes include polarity-specific redox layers and engineered hydrogel interfaces, configured for a bifrontotemporal montage. The stimulator design includes adaptive ramps with hybrid voltage-current control and low compliance voltage. Scanning electron microscopy (SEM) and electrical impedance spectroscopy (EIS) characterized electrode properties. Tolerability of HC-tDCS was tested at target currents of 1-6 mA (in 1 mA increments) for 30 min on 10 healthy subjects, and compared with conventional tDCS using 2 mA F3-F4 sponge-electrodes. Tolerability was assessed according to the 100 mm visual analogue scale for pain (VAS-P100), skin erythema assessment, thermal imaging, and adverse event questionnaires. MRI-derived computational models predicted brain electric fields. RESULTS: The electrode design incorporating roughened redox layers with polarity-specific electrochemical capacity supports high-charge direct current stimulation. In all subjects, HC-tDCS was well tolerated at all tested doses (1-6 mA) with minor transient adverse events. Mean VAS-P100 (±SD) was 17.17 ± 11.12 for 6 mA HC-tDCS and 18.30 ± 9.49 for 2 mA sponge-electrode tDCS. HC-tDCS operated at lower voltage than sponge-tDCS. Across MRI-derived head models, 6 mA HC-tDCS produced 2.25-3.26 V/m electric fields, ∼4x higher than conventional 2 mA tDCS electric fields of 0.49-0.85 V/m. 6 mA HC-tDCS electric fields can exceed 1 V/m across frontal cortical and deeper limbic regions, including the dorsolateral prefrontal cortex, anterior cingulate cortex, insula, and amygdala. CONCLUSIONS: HC-tDCS was well tolerated by participants and expands the accessible tDCS dose range, enabling stimulation up to at least 6 mA and substantially higher electric fields throughout cortical and deeper brain regions than conventional 2 mA tDCS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcranial Direct Current StimulationBrainHumansFemaleMaleElectrodesAdultYoung Adult

Autor:innen und Institutionen

  • Department of Biomedical Engineering, The City College of New York, CUNY, New York, NY, USA. Electronic address: kdonnery@ccny.cuny.edu.
  • Department of Biomedical Engineering, The City College of New York, CUNY, New York, NY, USA.
  • Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.

Förderung

  • National Institutes of Health

Zitieren

APA

Donnery, K., FallahRad, M., Osorio, S., Koochesfahani, M. B., Khadka, N., Saw, M., Mo, J., Babaev, B., Bhuiyan, R., Elwassif, J. M., & Bikson, M. (2026). High-capacity transcranial direct current stimulation (HC-tDCS). Brain Stimulation, 19(6), 103233. https://doi.org/10.1016/j.brs.2026.103233

Vancouver

Donnery K, FallahRad M, Osorio S, Koochesfahani MB, Khadka N, Saw M, et al. High-capacity transcranial direct current stimulation (HC-tDCS). Brain Stimulation. 2026;19(6):103233. doi:10.1016/j.brs.2026.103233

BibTeX
@article{Donnery2026,
  author = {Donnery, Kyle and FallahRad, Mohamad and Osorio, Santiago and Koochesfahani, Mojtaba Belali and Khadka, Niranjan and Saw, Matthew and Mo, Jinglin and Babaev, Benjamin and Bhuiyan, Rayyan and Elwassif, Jana M and Bikson, Marom},
  title = {High-capacity transcranial direct current stimulation (HC-tDCS)},
  journal = {Brain Stimulation},
  year = {2026},
  volume = {19},
  number = {6},
  pages = {103233},
  doi = {10.1016/j.brs.2026.103233}
}
Kostenlos starten →