EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimization of catheter placement for interstitial gynecological brachytherapy with centroidal Voronoi tessellation

Jillian Bennett, Cédric Bélanger, Philippe Y Chatigny, Ruiyan Ni, Luc Beaulieu, Alexandra Rink

Brachytherapy · 2026-10

DOI: 10.1016/j.brachy.2026.09.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Brachytherapy, 2026-10. Verfasst von Jillian Bennett und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Biophysics, University of Toronto, Toronto, Canada. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Canadian Institutes of Health Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the feasibility of using images taken after placement of the Template and APPlicator (post-TAPP) with a geometry-based catheter placement optimization to generate interstitial implants in locally advanced cervical cancer cases. METHODS AND MATERIALS: A processing pipeline with Centroidal Voronoi Tessellation (CVT)-based catheter optimization was used to retrospectively simulate optimized catheters on post-TAPP imaging from 32 cervix transperinneal interstitial brachytherapy cases using a Syed Neblett template (16 with iterative MR-guidance, 16 without). Treatment plans were generated with CVT-optimized and clinically implanted catheters. Improvement in plan quality and decrease in number of inserted catheters due to catheter optimization were evaluated against cases performed with and without intraoperative MR imaging. RESULTS: Use of CVT resulted in fewer unused catheters (mean reduction of ∼3) compared to the clinical cases performed both with and without MR imaging guidance, without an increase in %V150 or %V200. In non-MR-guided cases, use of CVT improved the EMBRACE-II limit compliance for D90% for CTVHR. This improvement was not observed in MR-guided procedures. CONCLUSION: This feasibility study suggests that post-TAPP CVT catheter optimization can achieve clinically acceptable dosimetry while limiting unnecessary catheters, showing a qualitative improvement in dosimetry compared to using preBrachy images alone for catheter selection.

Schlagwörter

Stichwörter der Autor:innen

CathetersCervical cancerFeasibility studiesMagnetic resonance imagingOptimization

Autor:innen und Institutionen

  • Department of Medical Biophysics, University of Toronto, Toronto, Canada.
  • Département de Physique, de Génie Physique et d'optique et Centre de Recherche Sur le Cancer de l'Université Laval, Québec, Canada; Service de Physique Médicale et Radioprotection et Centre de Recherche du CHU de Québec…
  • Department of Medical Biophysics, University of Toronto, Toronto, Canada; Princess Margaret Cancer Centre, University Health Network, Toronto, Canada; Department of Radiation Oncology, University of Toronto, Toronto, Ca…

Förderung

  • Natural Sciences and Engineering Research Council of Canada
  • Canadian Institutes of Health Research

Zitieren

APA

Bennett, J., Bélanger, C., Chatigny, P. Y., Ni, R., Beaulieu, L., & Rink, A. (2026). Optimization of catheter placement for interstitial gynecological brachytherapy with centroidal Voronoi tessellation. Brachytherapy. https://doi.org/10.1016/j.brachy.2026.09.006

Vancouver

Bennett J, Bélanger C, Chatigny PY, Ni R, Beaulieu L, Rink A. Optimization of catheter placement for interstitial gynecological brachytherapy with centroidal Voronoi tessellation. Brachytherapy. 2026. doi:10.1016/j.brachy.2026.09.006

BibTeX
@article{Bennett2026,
  author = {Bennett, Jillian and Bélanger, Cédric and Chatigny, Philippe Y and Ni, Ruiyan and Beaulieu, Luc and Rink, Alexandra},
  title = {Optimization of catheter placement for interstitial gynecological brachytherapy with centroidal Voronoi tessellation},
  journal = {Brachytherapy},
  year = {2026},
  doi = {10.1016/j.brachy.2026.09.006}
}
Kostenlos starten →