EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Is single implant and multiple fractions radio-biologically iso-effective for cervical cancer high-dose-rate brachytherapy: Observation from patient cohorts during COVID pandemic

Supriya Chopra, Asesh Samanta, Arunima Nagar, Prachi Mittal, Ankita Gupta, Jaahid Mulani, Jeevanshu Jain, Yogesh Ghadi, Prachi Sawant, Sushmita Rath, Jaya Ghosh, Sudeep Gupta

Brachytherapy · 2026-03 · 25 (2) · 291-299

DOI: 10.1016/j.brachy.2025.11.010 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Brachytherapy, 2026-03. Verfasst von Supriya Chopra und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Advanced Centre for Treatment Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institut…. Hauptthemen laut MEDLINE: Brachytherapy, Uterine Cervical Neoplasms, COVID-19. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To report clinical outcomes of cervical cancer patients treated with single implant and multiple fractions of high-dose-rate brachytherapy (HDR BT). MATERIALS AND METHODS: Patients treated with (chemo)radiation followed by single implant with all fractionated HDR BT delivered within 24-36 hours were included. Treatment protocol recommended >70 Gy equivalent doses in 2 Gy (EQD210Gy) at point A for intracavitary BT (ICBT) and >85 Gy EQD210Gy for those receiving interstitial-intracavitary BT (IC-ISBT). Local control, locoregional control and disease-free survival was estimated along with late gastrointestinal (GI) and genitourinary (GU) toxicity. RESULTS: From 2020-2022, 116 patients were treated with single implant multiple fractions HDR-BT. The median dose to Point A, HRCTV D90, B2cc, R2cc and S2cc was 75.1 (72.4-77.8), 80.2 (76-84), 85.2 (83.1-90.1), 69.1 (65.0-73.9) and 67.9 (61-75.3) Gy for those treated with ICBT. The median dose to high risk clinical target volume D90, Bladder 2cc, Rectum 2cc and Sigmoid 2cc was 83.2 (78.2-88.4), 87.4 (84.2-91), 69.6 (64.1-75) and 68.1 (59.5-77.1) Gy in those with IC-ISBT respectively. The median follow-up was 36 months (2-60 months). The 5-year local control, loco-regional control, disease free survival and overall survival was 89%, 84%, 70.8% and 81.6% respectively. Grade ≥3 GI and GU toxicity were 11.3% and 1.7% respectively. The incidence Grade ≥3 GI was higher in those who received 8-9 Gy in three fractions than 5-7.5 Gy in 3-4 fractions. CONCLUSION: The abbreviated HDR BT schedule of single implant 3-4 fractions for LACC patients is radiobiological iso-effective for tumor control. There seems to be a fraction size dependence of abbreviated fractionation schedule for severe GI toxicity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrachytherapyUterine Cervical NeoplasmsCOVID-19HumansFemaleMiddle AgedAgedDose Fractionation, RadiationAdultRadiotherapy DosageAged, 80 and overPandemicsTreatment OutcomeSARS-CoV-2

Autor:innen und Institutionen

  • Department of Radiation Oncology, Advanced Centre for Treatment Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, India. Electronic address: schopra@actrec.gov.in.
  • Department of Radiation Oncology, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, Maharashtra, India.
  • Department of Radiation Oncology, Advanced Centre for Treatment Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, India.
  • Department of Radiation Oncology & Medical Physics, Department of Radiation Oncology, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, Maharashtra, India.
  • Department of Medical Oncology, Tata Memorial Hospital, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, Maharashtra, India.

Zitieren

APA

Chopra, S., Samanta, A., Nagar, A., Mittal, P., Gupta, A., Mulani, J., Jain, J., Ghadi, Y., Sawant, P., Rath, S., Ghosh, J., & Gupta, S. (2026). Is single implant and multiple fractions radio-biologically iso-effective for cervical cancer high-dose-rate brachytherapy: Observation from patient cohorts during COVID pandemic. Brachytherapy, 25(2), 291-299. https://doi.org/10.1016/j.brachy.2025.11.010

Vancouver

Chopra S, Samanta A, Nagar A, Mittal P, Gupta A, Mulani J, et al. Is single implant and multiple fractions radio-biologically iso-effective for cervical cancer high-dose-rate brachytherapy: Observation from patient cohorts during COVID pandemic. Brachytherapy. 2026;25(2):291-299. doi:10.1016/j.brachy.2025.11.010

BibTeX
@article{Chopra2026,
  author = {Chopra, Supriya and Samanta, Asesh and Nagar, Arunima and Mittal, Prachi and Gupta, Ankita and Mulani, Jaahid and Jain, Jeevanshu and Ghadi, Yogesh and Sawant, Prachi and Rath, Sushmita and Ghosh, Jaya and Gupta, Sudeep},
  title = {Is single implant and multiple fractions radio-biologically iso-effective for cervical cancer high-dose-rate brachytherapy: Observation from patient cohorts during COVID pandemic},
  journal = {Brachytherapy},
  year = {2026},
  volume = {25},
  number = {2},
  pages = {291--299},
  doi = {10.1016/j.brachy.2025.11.010}
}
Kostenlos starten →