Automatic digitization of applicator and catheters for MRI-guided cervical cancer brachytherapy
Brachytherapy · 2026
DOI: 10.1016/j.brachy.2025.09.017 ↗Kurz gefasst
Fachartikel in der Zeitschrift Brachytherapy, 2026. Verfasst von Gayoung Kim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD. Hauptthemen laut MEDLINE: Brachytherapy, Uterine Cervical Neoplasms, Radiotherapy, Image-Guided, Magnetic Resonance Imaging. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
PURPOSE: MRI is the standard imaging modality for contouring organs-at-risk and clinical target volume in cervical cancer brachytherapy, and is widely used along with CT for treatment planning and image guidance. However, MRI-CT fusion-based approach is time-consuming and error-prone as it requires two imaging sessions and image registration. To realize more efficient and streamlined MRI-guided workflow, we propose an automatic method for digitizing the applicator and catheters using MRI alone. METHODS: Applicator digitization consists of applicator mesh reconstruction, applicator ring identification, and alignment of the mesh model with MRIs. For catheter digitization, we employ an uncertainty-aware deep-learning model that simultaneously segments catheters and computes uncertainty on its prediction. These uncertainty facilitate initial localization of the catheters and subsequent refinement. RESULTS: This study was performed on 35 T2-weighted MRIs from 30 cervical cancer patients treated with the Venezia applicator. The dataset was divided into 80% for development and 20% for testing. The method successfully digitized all applicators, with mean translation and rotation errors of 1.13 ± 0.26 mm and 2.19 ± 2.09°, respectively. All catheters except one were successfully digitized with shaft and tip errors of 0.74 ± 0.32 mm and 2.52 ± 2.04 mm, respectively. Furthermore, plans derived from the automatic digitization showed no significant differences compared to clinical plans (p > 0.05). CONCLUSION: The proposed MRI-based applicator and catheters digitization simplifies the brachytherapy planning process by eliminating the need for CT and manual tasks. Our results demonstrate that this approach is feasible and can be integrated into clinical workflows, offering potential improvements in efficiency and accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD.
- Elekta Inc, Washington, DC.
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD; Department of Medicine (Cardiology), Johns Hopkins University, Baltimore, MD.
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD. Electronic address: junghoon@jhu.edu.
Förderung
- NCI NIH HHS
- National Institutes of Health
Zitieren
APA
Kim, G., Antaki, M., Schmidt, E. J., Roumeliotis, M., Viswanathan, A. N., & Lee, J. (2026). Automatic digitization of applicator and catheters for MRI-guided cervical cancer brachytherapy. Brachytherapy. https://doi.org/10.1016/j.brachy.2025.09.017
Vancouver
Kim G, Antaki M, Schmidt EJ, Roumeliotis M, Viswanathan AN, Lee J. Automatic digitization of applicator and catheters for MRI-guided cervical cancer brachytherapy. Brachytherapy. 2026. doi:10.1016/j.brachy.2025.09.017
BibTeX
@article{Kim2026,
author = {Kim, Gayoung and Antaki, Majd and Schmidt, Ehud J and Roumeliotis, Michael and Viswanathan, Akila N and Lee, Junghoon},
title = {Automatic digitization of applicator and catheters for MRI-guided cervical cancer brachytherapy},
journal = {Brachytherapy},
year = {2026},
doi = {10.1016/j.brachy.2025.09.017}
}
EUVIMED