Surgically targeted radiation therapy versus stereotactic radiation therapy: A dosimetric comparison for brain metastasis resection cavities
Brachytherapy · 2024-11 · 23 (6) · 751-760
DOI: 10.1016/j.brachy.2024.06.007 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Brachytherapy, 2024-11. Verfasst von Tugce Kutuk und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, FL. Hauptthemen laut MEDLINE: Brain Neoplasms, Radiosurgery, Radiotherapy Dosage. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 51 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Surgically targeted radiation therapy (STaRT) with Cesium-131 seeds embedded in a collagen tile is a promising treatment for recurrent brain metastasis. In this study, the biological effective doses (BED) for normal and target tissues from STaRT plans were compared with those of external beam radiotherapy (EBRT) modalities. METHODS: Nine patients (n = 9) with 12 resection cavities (RCs) who underwent STaRT (cumulative physical dose of 60 Gy to a depth of 5 mm from the RC edge) were replanned with CyberKnifeⓇ (CK), Gamma KnifeⓇ (GK), and intensity modulated proton therapy (IMPT) using an SRT approach (30 Gy in 5 fractions). Statistical significance comparing D95% and D90% in BED10Gy (BED10Gy95% and BED10Gy90%) and to RC + 0 to + 5 mm expansion margins, and parameters associated with radiation necrosis risk (V83Gy, V103Gy, V123Gy and V243Gy) to the normal brain were evaluated by a Wilcoxon-signed rank test. RESULTS: For RC + 0 mm, median BED10Gy 90% for STaRT (90.1 Gy10, range: 64.1-140.9 Gy10) was significantly higher than CK (74.3 Gy10, range:59.3-80.4 Gy10, p = 0.04), GK (69.4 Gy10, range: 59.8-77.1 Gy10, p = 0.005), and IMPT (49.3 Gy10, range: 49.0-49.7 Gy10, p = 0.003), respectively. However, for the RC + 5 mm, the median BED10Gy 90% for STaRT (34.1 Gy10, range: 22.2-59.7 Gy10) was significantly lower than CK (44.3 Gy10, range: 37.8-52.4 Gy10), and IMPT (46.6 Gy10, range: 45.1-48.5 Gy10), respectively, but not significantly different from GK (34.1 Gy10, range: 22.8-47.0 Gy10). The median V243Gy was significantly higher in CK (11.7 cc, range: 4.7-20.1 cc), GK(6.2 cc, range: 2.3-11.9 cc) and IMPT (19.9 cc, range: 11.1-36.6 cc) compared to STaRT (1.1 cc, range: 0.0-7.8 cc) (p < 0.01). CONCLUSIONS: This comparative analysis suggests a STaRT approach may treat recurrent brain tumors effectively via delivery of higher radiation doses with equivalent or greater BED up to at least 3 mm from the RC edge as compared to EBRT approaches.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, FL.
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, FL; Department of Radiation Oncology, Herbert Wertheim College of Medicine, Florida International University, Miami, FL.
- Department of Neurosurgery, Miami Cancer Institute, Baptist Health South Florida, Miami, FL.
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, FL; Department of Radiation Oncology, Herbert Wertheim College of Medicine, Florida International University, Miami, FL. Ele…
Zitieren
APA
Kutuk, T., Kotecha, R., Herrera, R., Wieczorek, D. J. J., Fellows, Z. W., Chaswal, V., La Rosa, A., Mishra, V., McDermott, M. W., Siomin, V., Mehta, M. P., Gutierrez, A. N., & Tolakanahalli, R. (2024). Surgically targeted radiation therapy versus stereotactic radiation therapy: A dosimetric comparison for brain metastasis resection cavities. Brachytherapy, 23(6), 751-760. https://doi.org/10.1016/j.brachy.2024.06.007
Vancouver
Kutuk T, Kotecha R, Herrera R, Wieczorek DJJ, Fellows ZW, Chaswal V, et al. Surgically targeted radiation therapy versus stereotactic radiation therapy: A dosimetric comparison for brain metastasis resection cavities. Brachytherapy. 2024;23(6):751-760. doi:10.1016/j.brachy.2024.06.007
BibTeX
@article{Kutuk2024,
author = {Kutuk, Tugce and Kotecha, Rupesh and Herrera, Roberto and Wieczorek, D Jay J and Fellows, Zachary W and Chaswal, Vibha and La Rosa, Alonso and Mishra, Vivek and McDermott, Michael W and Siomin, Vitaly and Mehta, Minesh P and Gutierrez, Alonso N and Tolakanahalli, Ranjini},
title = {Surgically targeted radiation therapy versus stereotactic radiation therapy: A dosimetric comparison for brain metastasis resection cavities},
journal = {Brachytherapy},
year = {2024},
volume = {23},
number = {6},
pages = {751--760},
doi = {10.1016/j.brachy.2024.06.007}
}
EUVIMED